4 Conductors 22 AWG, PO Insulation, Double Shielded, TPE Inner Jacket, TPU Outer Jacket, PROFINET TYPE R Cable
Specifications
Specifications
Product Overview
| Suitable Applications | High Flex applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Conductors |
|---|
| 22 | Stranded | TC - Tinned Copper | 4 |
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PO - Polyolefin | 1.4 mm | 0.2 mm |
Color Chart
| Color |
|---|
| White & Yellow & Blue & Orange |
Inner Jacket
| Material |
|---|
| TPE - Thermoplastic Elastomer |
Cabling
| Filler | Number of Fillers |
|---|
| Yes | 5 |
Outer Shield
| Type | Material | Coverage [%] |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 90% |
| Braid | Tinned Copper (TC) | |
Outer Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PUR - Polyurethane | 7.1 mm | 0.2 mm |
Construction and Dimensions
| Min Elongation at Breakof Insulation | 150 % |
|---|
| Min Elongation at Breakof InsulAged | 70 % |
|---|
| Min Tensile Strength of Insulation Aged | 70 % |
|---|
| Min Tensile Strength at Breakof Insul | 20.7 MPa |
|---|
| Min Elongation at Breakof Jacket | 100 % |
|---|
| Min Tensile Strength of Jacket | 10.3 MPa |
|---|
| Min Tensile Strength of Jacket Aged | 70 % |
|---|
| Min Elongation at Break of Jacket Aged | 65 % |
|---|
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR |
|---|
| 59.4 Ohm/km |
Impedance
| Nominal Characteristic Impedance |
|---|
| 100 Ohm |
Delay
| Max. Delay Skew |
|---|
| 20 ns/100m |
Voltage
Temperature Range
| Operating Temperature Range | -20°C To +80°C |
|---|
Mechanical Characteristics
| Bending Test | Reverse bending test at bending radius 7D, weight 300 g, Speed 60 cycles/min : ≥ 1 million |
|---|
| Torsion Test: Min Number of Torsions | 5000000 |
|---|
| Torsion Test: Description | Stress : +/- 180°, weight : 300g, s=30 cycles/min, torsion length : 1000 mm |
|---|
| Flexibility Test | At 113°C x 168hrs: No cracking (for Insulation & Jacket) |
|---|
| Deformation Test for Insulation | ≤50 % |
|---|
| Deformation Test for Jacket | ≤50 % |
|---|
| Cold Bend Test | No Crack |
|---|
| IRM 902 Mineral Oil Resistance Test | At (100°Cx96hrs) - Tensile Strength of Jacket : ≥ 50% of original and Elongation of jacket : ≥ 50% of original |
|---|
| Min No. of Drag Chain Cycles | ≥ 5 million |
|---|
| Drag Chain Parameters | r=15 D, a= 10m/s^2, v= 180m/min, chain length : 5 m |
|---|
Standards
| UL AWM Style Compliance | AWM 20549 |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-6 |
|---|
| Data Category | Category 5e |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Oil Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC 60754-1 - Halogen Amount | HCl + HBr : According to EN60754-1 :≤0.5 %,
HF : According to EN 60684-2 : ≤0.1 % |
|---|
History
| Update and Revision | Revision Number: 0.15 Revision Date: 08-25-2022 |
|---|
Documentation
Product Bulletins
Warranties
Data Sheets