Speaker Cable, 4 Conductor 2.5mm² (50 x 0.25mm) Oxygen-Free Bare Copper (High Conductivity), LSZH Insulation, LSZH Jacket, Flexible, CPR Euroclass Dca.
Specifications
Specifications
Product Overview
Suitable Applications | Speaker cable for use in indoor or outdoor applications |
---|
Physical Characteristics (Overall)
Conductor
Stranding | Material | Cross Section | Construction n x D |
---|
Stranded | BC-OFHC - Oxygen-Free Bare Copper (High Conductivity) | 2.50 mm² | 50x0.25 mm |
Insulation
Type | Material | Nominal Diameter | Diameter +/- Tolerance |
---|
Insulation | LSZH - Low Smoke Zero Halogen (Flame Retardant) | 2.70 mm | 0.07 mm |
Color Chart
Number | Color |
---|
Wire 1 | Black |
Wire 2 | Red |
Wire 3 | White |
Wire 4 | Green |
Outer Jacket
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 8.50 mm | 0.20 mm |
Construction and Dimensions
Cabling
Description |
---|
1 center filler + 4 wires twisted |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR |
---|
8 Ohm/km |
Min Insulation Resistance | 200 MOhm*km |
---|
Voltage
Temperature Range
Storage Temperature Range | -30°C to +70°C |
---|
Operating Temp Range (Flexible Install) | -5°C To +60°C |
---|
Operating Temp Range (Fixed Install) | -30°C To +70°C |
---|
Mechanical Characteristics
Standards
CPR Euroclass | Dca-s2,d2,a1 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Euroclass Dca |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2 |
---|
LOI of Jacket | Min. 34 % |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
History
Update and Revision | Revision Number: 0.182 Revision Date: 12-16-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets