DIGITAL AUDIO 4 PAIR AES/EBU, 26AWG/0.14mm², ISTP, LSZH-C
Specifications
Specifications
Product Overview
| Suitable Applications | Digital multi-modulation cable used in professional studios for the transmission of analogue and digital audio signals; Designed to meet the requirements of the AES/EBU specification; Resistance to flame propagation according to IEC 60332-3-24 | 
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Cross Section | Construction n x D | 
|---|
| 26 | 7x34 | BC-OFHC - Oxygen-Free Bare Copper (High Conductivity) | 0.14 mm² | 7x0.15 mm | 
| Conductor Count | 8 | 
|---|
| Total Number of Pairs | 4 | 
|---|
Insulation
| Type | Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| Insulation | PE - Polyethylene (Foam) | 1.10 mm | 0.03 mm | 
Color Chart
| Number | Color | 
|---|
| Pair 1 t/m 4 | White & Blue | 
Inner Shield
| Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D | 
|---|
| Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Stranded tinned copper | 26 | 7x0.16 mm | 
| Table Notes | Aluminum inside | 
|---|
Inner Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 2.90 mm | 0.10 mm | 
| Table Notes | Elements are numbered for identification | 
|---|
Outer Shield
| Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | TC - Tinned Copper | 26 | 7x0.16 mm | 
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 9.80 mm | 1.20 mm | 
Construction and Dimensions
Cabling
| Description | Filler | 
|---|
| 1 filler + 4 pairs | Polypropylene | 
| Min Elongation at Breakof Jacket | 125 % | 
|---|
| Min Tensile Strength of Jacket | 9 MPa | 
|---|
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | 
|---|
| 134.0 Ohm/km | 
Capacitance
| Nom. Capacitance Conductor to Conductor | 
|---|
| 40 pF/m | 
Impedance
| Frequency [MHz] | Nominal Characteristic Impedance | Nominal Characteristic Tolerance | 
|---|
| 0.1 - 6 | 110 Ohm | +/- 15 Ohm | 
Delay
| Nominal Velocity of Propagation (VP) [%] | 
|---|
| 80% | 
Temperature Range
| Other Temp Range | -30 to +70 °C | 
|---|
Mechanical Characteristics
| Min. Bend Radius During Installation | 98 mm | 
|---|
| Min. Bend Radius During Operation | 147 mm | 
|---|
Standards
| CENELEC Compliance | EN 50290-2-20 | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor | 
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-3-24 | 
|---|
| IEC 60754-1 - Halogen Amount | Zero | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 | 
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% | 
|---|
History
| Update and Revision | Revision Number: 0.184    Revision Date: 12-20-2022 | 
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets