DIGITAL AUDIO 10 PAIR AES/EBU, 24AWG/0.22mm², ISTP, LSZH-C
Specifications
Specifications
Product Overview
| Suitable Applications | Digital multi-modulation cable used in professional studios for the transmission of analogue and digital audio signals.; Designed to meet the requirements of the AES/EBU specification |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 24 | 7x32 | BC-OFHC - Oxygen-Free Bare Copper (High Conductivity) | 10 |
| Conductor Count | 20 |
|---|
| Total Number of Pairs | 10 |
|---|
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PE - Polyethylene (Foam) | 1.45 mm | 0.03 mm |
Color Chart
| Number | Color |
|---|
| Pairs 1 t/m 10 | White & Blue |
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Stranded tinned copper | 24 |
Inner Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 3.5 mm | 0.1 mm |
| Table Notes | Elements are numbered for identification |
|---|
Outer Shield
| Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | TC - Tinned Copper | 24 | Stranded |
Outer Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 15.6 mm | 0.1 mm | 1.2 mm |
Construction and Dimensions
Cabling
| Description |
|---|
| 10 pairs + drainwire stranded tinnend copper (AWG24)(7x0.20mm) + Filler |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 86 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor |
|---|
| 40 pF/m |
Impedance
| Nominal Characteristic Impedance | Nominal Characteristic Tolerance |
|---|
| 110 Ohm | 15 Ohm |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 80% |
Temperature Range
| Other Temp Range | -30-+70 °C |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-3-24 |
|---|
| LOI of Jacket | 45 % |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|