DIGITAL AUDIO 4 PAIR AES/EBU, 22AWG/0.34mm², ISTP, LSZH-C
Specifications
Specifications
Product Overview
| Suitable Applications | Digital multi-modulation cable used in professional studios for the transmission of analogue and digital audio signals.; Designed to meet the requirements of the AES/EBU specification | 
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs | 
|---|
| 22 | 7x30 | BC-OFHC - Oxygen-Free Bare Copper (High Conductivity) | 4 | 
| Conductor Count | 8 | 
|---|
| Total Number of Pairs | 4 | 
|---|
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| PE - Polyethylene (Foam) | 2.1 mm | 0.05 mm | 
Color Chart
| Number | Color | 
|---|
| Pair 1 t/m 4 | Red & Black | 
Inner Shield
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D | Drainwire Position | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Stranded tinned copper | 22 | 7x0.25 mm | Under shielding foil | 
Inner Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 5.3 mm | 0.1 mm | 
| Table Notes | Elements are numbered for identification | 
|---|
Outer Shield
| Material | 
|---|
| Bi-Laminate (Alum+Poly) | 
Outer Jacket
| Material | Nominal Diameter | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 15.8 mm | 
Construction and Dimensions
Cabling
| Description | 
|---|
| 1 center filler + 4 pairs + stranded tinnend copper drainwire (22AWG)(7x0.25) covered with a non-woven foil | 
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | 
|---|
| 86 Ohm/km | 
Capacitance
| Nom. Capacitance Conductor to Conductor | 
|---|
| 40 pF/m | 
Impedance
| Nominal Characteristic Impedance | Nominal Characteristic Tolerance | 
|---|
| 110 Ohm | 15 Ohm | 
Delay
| Nominal Velocity of Propagation (VP) [%] | 
|---|
| 80% | 
Temperature Range
| Other Temp Range | -30-+70 °C | 
|---|
Mechanical Characteristics
Standards
| CPR Euroclass | Cca-s1,d1,a1 | 
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Cca | 
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes | 
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 | 
|---|
| IEC 60754-1 - Halogen Amount | Zero | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm | 
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 | 
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% | 
|---|
History
| Update and Revision | Revision Number: 0.19    Revision Date: 08-31-2022 | 
|---|
Documentation
Brochures and Guides
All Resources
Data Sheets