DataTuff® 5E, 2 Pair AWG 26 Bare Copper - Stranded, Polyethylene insulation, SF/UTP - Overall Braid + Foil shielding, LSZH / FRNC jacket , AWM 21286
Specifications
Specifications
Product Overview
| Suitable Applications | harsh environment, IIoT, factory or process automation, video, audio, data communication, etc. |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs | Number of Element |
|---|
| 26 AWG | 7x0.16 mm | BC - Bare Copper | 2 | 4 |
Insulation
| Material | Nom. Insulation Diameter | Color Code |
|---|
| PE - Polyethylene | 0.98 mm (0.039 in) | White/Blue & Blue, White/Orange & Orange |
Cable Core
| Description |
|---|
| 2 pairs and 2 fillers twisted to cable core covered with a polyester foil |
Outer Shield
| Shield Type | Material | Coverage |
|---|
| Tape | Bi-Laminate (Alum+Poly) | |
| Braid | Tinned Copper (TC) | 80% |
| Table Notes | Aluminum outside |
|---|
Outer Jacket
| Material | Nom. Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 6 mm (0.24 in) |
| Overall Cable Diameter (Nominal) | 6 mm (0.24 in) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
|---|
| 140 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
Delay
| Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 40 ns/100m | 60% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. RL (Return Loss) [dB] |
|---|
| 0.772 | | 67 | | 19.4 |
| 1 | 3.2 dB/100m | 65.3 | 63.8 | 20 |
| 4 | 6 dB/100m | 56.3 | 51.8 | 23 |
| 10 | 9.5 dB/100m | 50.3 | 43.8 | 25 |
| 16 | 12.1 dB/100m | 47.2 | 39.7 | 25 |
| 20 | 13.6 dB/100m | 45.8 | 37.8 | 25 |
| 25 | 15.3 dB/100m | 44.3 | 35.8 | 24.3 |
| 31.25 | 17.1 dB/100m | 42.9 | 33.9 | 23.6 |
| 62.5 | 24.8 dB/100m | 38.3 | 27.9 | 21.5 |
| 100 | 32 dB/100m | 35.3 | 23.8 | 20.1 |
Voltage
| Voltage Rating |
|---|
| 450 V DC and 300 V AC |
Mechanical Characteristics
Temperature
| Operating | Installation | Storage |
|---|
| -40°C to +80°C | -5°C To +50°C | -40°C To +80°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 30 mm (1.2 in) | 60 mm |
| Max. Pull Tension | 40 N (9.0 lbf) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Euroclass Eca, Sunlight Resistance, Oil Resistance |
|---|
| Flammability / Reaction to Fire | IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
|---|
| Data Category | Category 5e |
|---|
| TIA/EIA Compliance | ANSI/TIA 568.2-D |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1 |
|---|
| CENELEC Compliance | EN 50173-1 |
|---|
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
|---|
| European Directive Compliance | EU CE Mark |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
History
| Update and Revision | Revision Number: 0.260 Revision Date: 12-20-2022 |
|---|
Documentation
Product Bulletins
Warranties
Compliance Documentation
Data Sheets