| Suitable Applications | Flex Data, RS232, RS422 |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 24 | 41x40 | BC - Bare Copper | 1 |
| Conductor Count | 2 |
|---|
| Total Number of Pairs | 1 |
|---|
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene (Foam) | 0.0555 in |
Color Chart
Outer Shield
| Type | Layer | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | 1 | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 24 | 41x40 |
| Braid | 2 | Tinned Copper (TC) | | 85% | | | |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PVC - Polyvinyl Chloride | 0.232 in | 0.045 in |
Electrical Characteristics
Capacitance
| Max. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Conductor |
|---|
| 14 pF/ft | 14 pF/ft |
| Min Insulation Resistance | 6.1 Megaohms/1000 |
|---|
Impedance
| Max. Differential Impedance (1MHz) |
|---|
| 100 +/-15 |
Delay
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 72% |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS |
Temperature Range
| UL Temp Rating | 60°C |
|---|
| Operating Temperature Range | -20°C To +60°C |
|---|
Mechanical Characteristics
| Oil Resistance | Yes |
|---|
| Flex Cycle Rating | 1 Million |
|---|
| Bulk Cable Weight | 33.4 lbs/1000ft |
|---|
| Max. Pull Tension | 41 lbs |
|---|
| Min. Bend Radius (Continuous Flexing) | 3.5 in |
|---|
| Min. Bend Radius/Minor Axis | 2.3 in |
|---|
Standards
| NEC Articles | Article 800 |
|---|
| NEC/(UL) Compliance | CM |
|---|
| CEC/C(UL) Compliance | CM |
|---|
| Other Specification | RS Type: 232/485 |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Oil Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 UL Loading |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
Product Notes
| Notes | 1 million flex cycles based on proper installation in a C-track cable guide. |
|---|