DataTuff® 7, 4 Pair AWG 26 Bare Copper - Stranded, Polyethylene insulation, S/FTP - Overall Braid / Individual Foil shielding, PUR Halogen Free jacket , AWM 21292
Specifications
Specifications
Product Overview
Suitable Applications | harsh environment, IIoT, factory or process automation, video, audio, data communication, etc. |
---|
Construction Details
Conductor
Size | Stranding | Material | Number of Pairs | Number of Element |
---|
26 AWG | 7x0.16 mm | BC - Bare Copper | 4 | 8 |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
PE - Polyethylene (Foam) | 1.05 mm (0.0413 in) | White/Blue & Blue, White/Orange & Orange, White/Green & Green, White/Brown & Brown |
Cable Core
Description |
---|
4 pairs twisted to cable core |
Inner Shield
Element | Shield Type | Material |
---|
Individual Shielded Pair | Tape | Bi-Laminate (Alum+Poly) |
Table Notes | Aluminum outside |
---|
Outer Shield
Shield Type | Material | Coverage |
---|
Braid | Tinned Copper (TC) | 65% |
Outer Jacket
Material | Nom. Diameter |
---|
PUR - Polyurethane (Halogen Free) | 6.8 mm (0.27 in) |
Table Notes | Flame Retardant Sheath |
---|
Overall Cable Diameter (Nominal) | 6.8 mm (0.27 in) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|
145 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
Delay
Max. Delay Skew | Nom. Velocity of Prop. |
---|
40 ns/100m | 70% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] |
---|
1 | 2.7 | 80 | 77 | | | |
4 | 5.5 | 80 | 77 | 58 | 55 | 23 |
10 | 8.5 | 80 | 77 | 50 | 47 | 25 |
16 | 10.8 | 80 | 77 | 46 | 43 | 25 |
20 | 12.1 | 80 | 77 | 44 | 41 | 25 |
31.25 | 15.2 | 80 | 77 | 40 | 37 | 23.6 |
62.5 | 21.8 | 75.1 | 72.1 | 34 | 31 | 21.5 |
100 | 27.8 | 72.4 | 69.4 | 30 | 27 | 20.1 |
200 | 40.1 | 67.9 | 64.9 | 24 | 21 | 18 |
300 | 50 | 65.3 | 62.3 | 20 | 17 | 17.3 |
600 | 73.3 | 60.8 | 57.8 | 14 | 11 | 17.3 |
Transfer Impedance
Frequency | Max. Transfer Impedance |
---|
10 Mhz | Max. 5 mOhm/m |
Voltage
UL Voltage Rating | Voltage Rating |
---|
30 V RMS | 450 V DC and 300 V AC |
Mechanical Characteristics
Temperature
Operating | Installation | Storage |
---|
-40°C to +80°C | -15°C To +60°C | -40°C to +80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
30 mm (1.2 in) | 65 mm |
Max. Pull Tension | 80 N (18 lbf) |
---|
Standards and Compliance
Environmental Suitability | Indoor, Indoor, Sunlight Resistance, Oil Resistance |
---|
Flammability / Reaction to Fire | IEC 60332-1-2 |
---|
AWM Compliance | AWM 21292 |
---|
Data Category | Category 7 |
---|
TIA/EIA Compliance | ANSI/TIA 568.2-D |
---|
ISO/IEC Compliance | ISO/IEC 11801-1 |
---|
CENELEC Compliance | EN 50173-1 |
---|
European Halogen Free Standards | IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
---|
European Directive Compliance | EU CE Mark |
---|
History
Update and Revision | Revision Number: 0.259 Revision Date: 03-04-2023 |
---|