MachFlex™ for High Flex, 17+1G Conductor 18AWG (16x30) Bare Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(85%) Shield, TPE Outer Jacket, 1000V WTTC, 600V TC-ER
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| Element | AWG | Stranding | Material | No. of Conductors |
|---|
| 18 | 16x30 | BC - Bare Copper | 17 |
| Ground Wire | 18 | 16x30 | BC - Bare Copper | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| PVC/Nylon - Polyvinyl Chloride + Nylon | 0.089 in |
Color Chart
| Number | Color |
|---|
| 1 | Black and Numbered 1 |
| 2 | Black and Numbered 2 |
| 3 | Black and Numbered 3 |
| 4 | Black and Numbered 4 |
| 5 | Black and Numbered 5 |
| 6 | Black and Numbered 6 |
| 7 | Black and Numbered 7 |
| 8 | Black and Numbered 8 |
| 9 | Black and Numbered 9 |
| 10 | Black and Numbered 10 |
| 11 | Black and Numbered 11 |
| 12 | Black and Numbered 12 |
| 13 | Black and Numbered 13 |
| 14 | Black and Numbered 14 |
| 15 | Black and Numbered 15 |
| 16 | Black and Numbered 16 |
| 17 | Black and Numbered 17 |
| 18 | Green/Black |
Inner Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| TPE - Thermoplastic Elastomer | 0.5 in | 0.025 in |
Outer Shield
| Type | Material | Coverage [%] | Nominal Diameter |
|---|
| Braid | Tinned Copper (TC) | 85% | 0.528 in |
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| TPE - Thermoplastic Elastomer | 0.654 in | 0.063 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 6.5 Ohm/1000ft |
Voltage
| UL Voltage Rating |
|---|
| 1000 V RMS |
| 600 V RMS |
Temperature Range
| UL Temp Rating | 75°C Dry, 90°C Wet |
|---|
| Other Temp Range | Flexing: -5°C To +90 °C |
|---|
Mechanical Characteristics
| Oil Resistance | Yes |
|---|
| Flex Cycle Rating | 1 Million Flexes |
|---|
| Bulk Cable Weight | 263 lbs/1000ft |
|---|
| Max. Pull Tension | 414 lbs |
|---|
| Min. Bend Radius (Continuous Flexing) | 6.5 in |
|---|
Standards
| NEC/(UL) Compliance | TC-ER, WTTC |
|---|
| CEC/C(UL) Compliance | CIC, TC |
|---|
| UL AWM Style Compliance | AWM 20328 |
|---|
| CSA AWM Compliance | AWM I/II A/B |
|---|
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Non-Halogenated | No |
|---|
| Suitability - Oil Resistance | Yes - Oil Res II |
|---|
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 UL Loading |
|---|
| CSA Flammability | FT4 |
|---|
| IEEE Flammability | 1202 |
|---|
| UL voltage rating | 1000 V RMS |
|---|
Plenum/Non-Plenum
History
| Update and Revision | Revision Number: 0.185 Revision Date: 05-05-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Case Studies
Warranties
Data Sheets