MachFlex™ for High Flex, 3+1G Conductor 16AWG (26x30) Bare Copper, PVC-NYL Insulation, Overall Tinned Copper Braid(85%) Shield, TPE Inner Jacket, TPE Outer Jacket, 1000V WTTC, 600V TC-ER
Specifications
Specifications
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | 
|---|
| Conductor(s) | 3 | 16 AWG | 26x30 | BC - Bare Copper | 
| Ground Wire | 1 | 16 AWG | 26x30 | BC - Bare Copper | 
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | 
|---|
| Conductor(s) | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.021 in (0.53 mm) | 0.101 in (2.57 mm) | Black and Numbered | 
| Ground Wire | PVC/Nylon - Polyvinyl Chloride + Nylon | 0.021 in (0.53 mm) | 0.101 in (2.57 mm) | Green/Yellow | 
Outer Shield
| Shield Type | Material | Coverage | 
|---|
| Braid | Tinned Copper (TC) | 85% | 
Inner Jacket
| Separator | Material | Nom. Thickness | Nom. Diameter | Color | 
|---|
| non-Woven Tape | TPE - Thermoplastic Elastomer | 0.25 in (6.4 mm) | 0.298 in (7.57 mm) | Chrome | 
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | 
|---|
| TPE - Thermoplastic Elastomer | 0.047 in (1.2 mm) | 0.42 in | 
| Overall Cable Diameter (Nominal) | 0.42 in | 
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Max. Current | 
|---|
| Conductor(s) | 4.18 Ohm/1000ft | 19 Amps per Conductor at 30ºC | 
| Ground Wire | 4.45 Ohm/1000ft (14.6 Ohm/km) | 30.4 Amps per Conductor at 30ºC | 
Voltage
| UL Voltage Rating | 
|---|
| 1000 V (WTTC), 600 V (TC-ER) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| UL : 90°C Dry, 75°C Wet; AWM 20328 : 105°C | -40°C To 105°C | 
Bend Radius
| Stationary Min. | Installation Min. | 
|---|
| 1.68 in (42.7 mm) | 2.1 in | 
| Max. Pull Tension | 160 lbs (73 kg) | 
|---|
| Bulk Cable Weight | 122 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance | 
|---|
| Flammability / Reaction to Fire | UL1685 UL Loading, IEEE 1202 FT4 | 
|---|
| NEC / UL Compliance | Article 336 | 
|---|
| AWM Compliance | AWM 20328, AWM I/II A/B | 
|---|
| CEC / C(UL) Compliance | CIC, TC | 
|---|
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
History
| Update and Revision | Revision Number: 0.248    Revision Date: 05-05-2023 | 
|---|