Physical Characteristics (Overall)
Conductor
Element | AWG | Stranding | Material | No. of Conductors |
---|
| 16 | 26x30 | BC - Bare Copper | 17 |
Ground Wire | 16 | 26x30 | BC - Bare Copper | 1 |
Insulation
Material | Nominal Diameter |
---|
PVC/Nylon - Polyvinyl Chloride + Nylon | 0.101 in |
Color Chart
Number | Color |
---|
1 | Black and Numbered 1 |
2 | Black and Numbered 2 |
3 | Black and Numbered 3 |
4 | Black and Numbered 4 |
5 | Black and Numbered 5 |
6 | Black and Numbered 6 |
7 | Black and Numbered 7 |
8 | Black and Numbered 8 |
9 | Black and Numbered 9 |
10 | Black and Numbered 10 |
11 | Black and Numbered 11 |
12 | Black and Numbered 12 |
13 | Black and Numbered 13 |
14 | Black and Numbered 14 |
15 | Black and Numbered 15 |
16 | Black and Numbered 16 |
17 | Black and Numbered 17 |
18 | Green/Yellow |
Inner Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
TPE - Thermoplastic Elastomer | 0.56 in | 0.025 in |
Outer Shield
Type | Material | Coverage [%] | Nominal Diameter |
---|
Braid | Tinned Copper (TC) | 85% | 0.588 in |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
TPE - Thermoplastic Elastomer | 0.714 in | 0.063 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
4 Ohm/1000ft |
Voltage
UL Voltage Rating |
---|
1000 V RMS |
600 V RMS |
Temperature Range
UL Temp Rating | 75°C Dry, 90°C Wet |
---|
Other Temp Range | Flexing: -5°C To +90 °C |
---|
Mechanical Characteristics
Oil Resistance | Yes |
---|
Flex Cycle Rating | 1 Million Flexes |
---|
Bulk Cable Weight | 351 lbs/1000ft |
---|
Max. Pull Tension | 630 lbs |
---|
Min. Bend Radius (Continuous Flexing) | 7.15 in |
---|
Standards
NEC/(UL) Compliance | TC-ER, WTTC |
---|
CEC/C(UL) Compliance | CIC, TC |
---|
UL AWM Style Compliance | AWM 20328 |
---|
CSA AWM Compliance | AWM I/II A/B |
---|
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Non-Halogenated | No |
---|
Suitability - Oil Resistance | Yes - Oil Res II |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
CSA Flammability | FT4 |
---|
IEEE Flammability | 1202 |
---|
UL voltage rating | 1000 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.375 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Case Studies
Warranties
Data Sheets