75 Ohm SDI Coax, RG-11, 14 AWG Solid Bare Copper Conductor, PE Insulation, Foil + 95% Tinned Copper Braid Shield, LSZH Jacket, CMG-LS, Shipboard ABS Type Approved
Specifications
Specifications
Product Overview
| Suitable Applications | Digital Video, HD-SDI 1080p, ABS approved for marine shipboard and offshore use | 
|---|
Construction Details
Conductor
| Size | Stranding | Nom. Diameter | Material | 
|---|
| 14 AWG | Solid | 0.064 in | BC - Bare Copper | 
Insulation
| Material | Nom. Insulation Diameter | Color Code | 
|---|
| PE - Polyethylene (Foam) | 0.280 in (7.11 mm) | White | 
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage | 
|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% | 
| 2 | Braid | Tinned Copper (TC) |  | 95% | 
Outer Jacket
| Material | Nom. Diameter | 
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.400 in (10.2 mm) | 
| Overall Cable Diameter (Nominal) | 0.400 in (10.2 mm) | 
|---|
Electrical Characteristics
Return Loss
| Frequency | Min. Return Loss | 
|---|
| 5 - 850 MHz | 23 dB | 
| 850 - 3000 MHz | 21 dB | 
Attenuation
| Frequency | Nom. Attenuation | 
|---|
| 1 MHz | 0.16 dB/100ft | 
| 3.58 MHz | 0.29 dB/100ft | 
| 5 MHz | 0.34 dB/100ft | 
| 7 MHz | 0.39 dB/100ft | 
| 10 MHz | 0.46 dB/100ft | 
| 67.5 MHz | 1.05 dB/100ft | 
| 71.5 MHz | 1.09 dB/100ft | 
| 88.5 MHz | 1.21 dB/100ft | 
| 100 MHz | 1.28 dB/100ft | 
| 135 MHz | 1.47 dB/100ft | 
| 143 MHz | 1.51 dB/100ft | 
| 180 MHz | 1.69 dB/100ft | 
| 270 MHz | 2.09 dB/100ft | 
| 360 MHz | 2.45 dB/100ft | 
| 540 MHz | 3.06 dB/100ft | 
| 720 MHz | 3.58 dB/100ft | 
| 750 MHz | 3.66 dB/100ft | 
| 800 MHz | 3.79 dB/100ft | 
| 1000 MHz | 4.3 dB/100ft | 
| 1500 MHz | 5.5 dB/100ft | 
| 2000 MHz | 6.4 dB/100ft | 
| 2250 MHz | 6.9 dB/100ft | 
| 3000 MHz | 8.2 dB/100ft | 
| 4500 MHz | 10.4 dB/100ft | 
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance 
        Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. | 
|---|
| 2.5 Ohm/1000ft | 1.5 Ohm/1000ft (4.9 Ohm/km) | 16.1 pF/ft (52.8 pF/m) | 75 Ohm | 84% | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V (CMG) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 75°C | -30°C to +75°C | 
Bend Radius
| Installation Min. | 
|---|
| 4 in (100 mm) | 
| Max. Pull Tension | 145 lbs (65.8 kg) | 
|---|
| Bulk Cable Weight | 89 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor, Aerial - Black only, When supported by messenger wire | 
|---|
| Sustainability | CA Prop 65 | 
|---|
| Flammability / Reaction to Fire | UL1685 FT4 Loading, Limited Smoke, 1202, IEC 60332-1-2, IEC 60332-3-22 | 
|---|
| CPR Compliance | CPR Euroclass: Dca-s2,d1,a1 | 
|---|
| NEC / UL Compliance | CMG-LS | 
|---|
| CEC / C(UL) Compliance | CMG-LS | 
|---|
| IEEE Compliance | Std. 45 clause 23 | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| UK Regulation Compliance | UKCA Mark | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
History
| Update and Revision | Revision Number: 0.507    Revision Date: 04-25-2023 | 
|---|
Documentation
Product Bulletins
Catalogs
Tools
Reference Manuals
Compliance Documentation
Data Sheets