50 Ohm Wireless Transmission Coax, RG-8, 10 AWG Solid Bare Copper Conductor , FEP Insulation, Foil + 90% Tinned Copper Braid Shield, PVDF Jacket, CMP, Low Loss
Specifications
Specifications
Product Overview
Suitable Applications | Point-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification) |
---|
Construction Details
Conductor
Size | Stranding | Nom. Diameter | Material |
---|
10 AWG | Solid | 0.108 in | BC - Bare Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
FEP - Fluorinated Ethylene Propylene (Foam) | 0.280 in (7.11 mm) | White |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
2 | Braid | Tinned Copper (TC) | | 90% |
Outer Jacket
Material | Nom. Diameter |
---|
PVDF - Polyvinylidene Fluoride | 0.355 in (9.02 mm) |
Overall Cable Diameter (Nominal) | 0.355 in (9.02 mm) |
---|
Electrical Characteristics
Attenuation
Frequency | Nom. Attenuation |
---|
1 MHz | 0.1 dB/100ft |
10 MHz | 0.4 dB/100ft |
50 MHz | 1.1 dB/100ft |
100 MHz | 1.5 dB/100ft |
200 MHz | 2.1 dB/100ft |
400 MHz | 3.2 dB/100ft |
700 MHz | 4.5 dB/100ft |
900 MHz | 5.7 dB/100ft |
1000 MHz | 5.9 dB/100ft |
4000 MHz | 14.1 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
0.9 Ohm/1000ft | 1.8 Ohm/1000ft (5.9 Ohm/km) | 24.2 pF/ft (79.4 pF/m) | 50 Ohm | 84% |
Voltage
UL Voltage Rating |
---|
300 V (CMP, CL2P) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
150°C | -20°C to +150°C |
Bend Radius
Installation Min. |
---|
3.6 in (91 mm) |
Max. Pull Tension | 174 lbs (78.9 kg) |
---|
Bulk Cable Weight | 115 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor - Plenum, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger wire |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | NFPA 262 |
---|
NEC / UL Compliance | CL2P, CMP |
---|
CEC / C(UL) Compliance | CMP |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
History
Update and Revision | Revision Number: 0.458 Revision Date: 04-14-2023 |
---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training
Compliance Documentation
Data Sheets