Belden

777940T - MarineTuff® 6, 4 Pr #23 Sol BC, PO Ins, LSZH Jkt, Brnz Brd Armor, LSZH Jkts, CMG-LS, ABS

(No reviews yet) Write a Review
SKU:
777940T
Shipping:
Calculated at Checkout
$0.00

Description

Industrial Ethernet Cat 6, 4 Bonded Pair 23AWG (Solid) Bare Copper, PO Insulation, LSZH Jacket, Flame Retardant Tape, LSZH Jacket, Bronze Braid Armor, LSZH Outer Jacket, CMG-LS, ABS

Specifications

Specifications

Put-Up TypeReel
Length305 m

Product Overview

Suitable Applicationsmarine, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force,

Construction Details

Conductor

ElementSizeStrandingMaterialNumber of PairsNumber of Element
Pair(s)23 AWGSolidBC - Bare Copper44

Insulation

MaterialColor Code
PO - PolyolefinWhite/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Bonded-PairYes

Inner Jacket

SeparatorMaterialNom. Diameter
LSZH - Low Smoke Zero Halogen (Flame Retardant)0.274 in (6.96 mm)
Aramid TapeLSZH - Low Smoke Zero Halogen (Flame Retardant)0.328 in (8.33 mm)

Armor

Armor Type & MaterialCoverage
BBA - Bronze Braid Armor80%

Outer Jacket

MaterialNom. Diameter
LSZH - Low Smoke Zero Halogen (Flame Retardant)0.463 in (11.8 mm)
Overall Cable Diameter (Nominal)0.463 in (11.8 mm)

Electrical Characteristics

Electricals

Max. Conductor DCRMax. Capacitance Unbalance
93.8 Ohm/km (28.6 Ohm/1000ft)330 pF/100m

Delay

FrequencyMax. DelayMax. Delay SkewNom. Velocity of Prop.
100 MHz537 ns/100m45 ns/100m69%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted) [Ohm]Max./Min. Fitted Impedance [Ohm]Min. TCL [dB]Min. ELTCTL [dB]
12.0 dB/100m74.372.372.370.367.864.820100 ± 15100 ± 1540.035.0
43.8 dB/100m65.363.361.559.555.852.723100 ± 15100 ± 1540.023.0
85.3 dB/100m60.858.855.453.449.746.724.5100 ± 15100 ± 1540.016.9
106 dB/100m59.357.353.351.347.844.825100 ± 15100 ± 1540.015.0
167.6 dB/100m56.254.348.746.743.740.725100 ± 15100 ± 1538.010.9
208.5 dB/100m54.852.846.344.341.838.825100 ± 15100 ± 1537.09.0
259.5 dB/100m53.351.343.841.839.836.824.3100 ± 15100 ± 1536.07.0
31.2510.7 dB/100m51.949.941.239.237.934.923.6100 ± 15100 ± 1535.15.1
62.515.4 dB/100m47.445.4323031.928.921.5100 ± 15100 ± 1532.0
10019.8 dB/100m44.342.324.522.527.824.820.1100 ± 15100 ± 1530.0
15525.2 dB/100m41.539.516.314.323.920.918.8100 ± 20100 ± 1528.1
20029.0 dB/100m39.837.810.88.821.818.818100 ± 20100 ± 1527.0
25032.8 dB/100m38.336.35.53.519.816.817.3100 ± 20100 ± 1526.0

Mechanical Characteristics

Temperature

UL TemperatureOperatingInstallationStorage
75°C-40°C To +75°C0°C To +60°C-40°C To +75°C

Bend Radius

Installation Min.
4.7 in (120 mm)
Max. Pull Tension40 lbs (18 kg)
Bulk Cable Weight122 lbs/1000ft

Standards and Compliance

Environmental SuitabilityMarine, Indoor, Outdoor, Non-Halogenated, Sunlight Resistance
Flammability / Reaction to FireUL CMG-LS, FT4, IEEE 1202
NEC / UL ComplianceArticle 800
CEC / C(UL) ComplianceCMG-ST1
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data CategoryCategory 6
TIA/EIA ComplianceCategory 6 - TIA 568.2-D
ISO/IEC ComplianceIEC 61034-2 - Smoke Density Min Transmittance = IEC 60332-3-22
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = Jacket only
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesJacket sequentially marked at 2 ft. intervals.

History

Update and RevisionRevision Number: 0.226 Revision Date: 01-20-2023
View AllClose