Digital Coax Snake Cable, Riser-CMR, 3-RG59 20 AWG, solid bare copper conductors, foam HDPE core, Duofoil® +95% tinned copper braid, PVC jacket
Specifications
Specifications
Product Overview
Suitable Applications | SMPTE 2081-1 6 Gb/s UHDTV, SMPTE 424M 3 Gb/s HD-SDI 1080p, SDI/HDTV Digital Video, High Definition (HD), Standard Definition (SDI) |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
20 | Solid | BC - Bare Copper | 0.032 in | 3 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene (Foam) | 0.145 in |
Color Chart
Number | Color |
---|
1 | Red |
2 | Green |
3 | Blue |
Inner Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Tinned Copper (TC) | | 95% |
Inner Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.235 in |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.631 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Inner Shield DCR | Outer Conductor DCR |
---|
10 Ohm/1000ft | 10 Ohm/1000ft | 3.8 Ohm/1000ft | 3.8 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
16.2 pF/ft |
Inductance
Nominal Inductance |
---|
0.107 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Minimum Return (RL) |
---|
5-1600 MHz | 23 dB |
1600-4500 MHz | 21 dB |
4500-6000 MHz | 15 dB |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.3 dB/100ft |
3.6 MHz | 0.6 dB/100ft |
10 MHz | 0.9 dB/100ft |
71.5 MHz | 2.1 dB/100ft |
135 MHz | 2.7 dB/100ft |
270 MHz | 3.8 dB/100ft |
360 MHz | 4.4 dB/100ft |
540 MHz | 5.5 dB/100ft |
720 MHz | 6.4 dB/100ft |
750 MHz | 6.5 dB/100ft |
1000 MHz | 7.6 dB/100ft |
1500 MHz | 9.4 dB/100ft |
2500 MHz | 12.4 dB/100ft |
3000 MHz | 13.8 dB/100ft |
4500 MHz | 18 dB/100ft |
6000 MHz | 21.1 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.22 ns/ft | 83% |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Non-UL Temp Rating | 75°C |
---|
UL Temp Rating | 60°C |
---|
Operating Temperature Range | -35°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 171 lbs/1000ft |
---|
Max. Pull Tension | 216 lbs |
---|
Min. Bend Radius/Minor Axis | 6.5 in |
---|
Standards
NEC/(UL) Compliance | CMR |
---|
CEC/C(UL) Compliance | CMG |
---|
CPR Euroclass | Eca |
---|
RG Type | 59 |
---|
Series Type | 59 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor/Outdoor |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Burial | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes - Black only |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1666 Vertical Shaft |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.399 Revision Date: 12-19-2022 |
---|
Documentation
Catalogs
Technical Resources
Data Sheets