Belden
7824R - 3-Channel SMPTE Stadium Cable, 6 Fiber, 6 Conductor 18 AWG, 6 Conductor 24 AWG, CMR
- SKU:
- 7824R
- Shipping:
- Calculated at Checkout
Description
3-Channel SMPTE Stadium Cable, 6 Single Mode Fiber, 6 TC Conductor (19x30) 18 AWG and 6 TC Conductor (7x32) 24 AWG, PVC Insulation, Beldfoil Shield, PVC Jacket, Riser
Specifications
Specifications
Product Overview
Suitable Applications | 3 Channel Composite Camera Cable |
---|
Multiconductor
Multiconductor Conductor and Insulation
Element | No. of Conductors | AWG | Stranding | Material | Nominal Conductor DCR | Insulation Material | Insulation Nominal Diameter |
---|---|---|---|---|---|---|---|
Quad 1, Quad 2, Quad 3 | 6 | 24 | 7x32 | TC - Tinned Copper | 23.3 Ohm/1000ft | PVC - Polyvinyl Chloride | 0.038 in |
Quad 1, Quad 2, Quad 3 | 6 | 18 | 19x30 | TC - Tinned Copper | 6.67 Ohm/1000ft | PVC - Polyvinyl Chloride | 0.080 in |
Multiconductor Color Chart
Description | Color |
---|---|
Quad 1 - 24 AWG | Red |
Quad 1 - 24 AWG | Gray |
Quad 1 - 18 AWG | White |
Quad 1 - 18 AWG | Black |
Quad 2 - 24 AWG | Red/Yellow |
Quad 2 - 24 AWG | Gray/Yellow |
Quad 2 - 18 AWG | White/Yellow |
Quad 2 - 18 AWG | Black/Yellow |
Quad 3 - 24 AWG | Red/Orange |
Quad 3 - 24 AWG | Gray/Orange |
Quad 3 - 18 AWG | White/Orange |
Quad 3 - 18 AWG | Black/Orange |
Shielding | Multiple or Specialty |
---|
Multiconductor Inner Shield
Layer | Inner Shield Type | Inner Shield Material | Inner Shield Coverage | Drainwire AWG | Drainwire Stranding | Drainwire Material | Drainwire Diameter | Drainwire Position |
---|---|---|---|---|---|---|---|---|
Each Quad | Tape | Al/poly (Foil in) | 100.0 % | 22 | 7x30 | TC - Tinned Copper | 0.030 in | Under Each Quad's Shield Tape |
Multiconductor UL Voltage
UL Description | UL Voltage Rating |
---|---|
24 AWG | 300 V RMS |
18 AWG | 300 V RMS |
Fiber
Fiber Cable Construction
Fiber Type | Fiber Count |
---|---|
OS2, G.657.A2 | 6 |
Fiber Color Coding | Yellow Printed |
---|
Buffer Specification
Buffer Material | Buffer Diameter |
---|---|
PVC - Polyvinyl Chloride | 900 µm |
Number of Active Subunits | 6 |
---|---|
Number of Subunit Positions | 6 |
Fibers Per Subunit | 1 |
Mode Field Diameter | 9.2 µm |
Wavelength@Optical SM1 | 1310 nm, 1550 nm |
Max. Attenuation at 1310 nm | 0.50 dB/km |
Max. Attenuation at 1550 nm | 0.50 dB/km |
Overall Cable
Conductor Material: | Tinned Copper |
---|
Outer Jacket
Material |
---|
PVC - Polyvinyl Chloride |
Jacket | PVC |
---|---|
Nominal Diameter@OuterJacket1 1_CP_OV | .525 in |
Operating Temperature Range | -20°C to 60°C |
Max. Pull Tension | 167 lbs |
Bulk Cable Weight | 161 lbs/1000ft |
Applicable Standards & Environmental Programs
NEC/(UL) Compliance | CMR |
---|---|
CEC/C(UL) Compliance | CMG |
Other Standards | SMPTE 311 |
EU Directive 2011/65/EU (RoHS 2) | Yes |
EU Directive 2000/53/EC (ELV) | Yes |
EU Directive 2012/19/EU (WEEE) | Yes |
CA Prop 65 (CJ for Wire and Cable) | Yes |
China RoHS II (GB/T 26572-2011) | Yes |
Suitability
Suitability - Indoor | Yes |
---|
Flame Test
CSA/C(UL) Flammability | UL 1666 Vertical Shaft |
---|
Plenum/Non-Plenum
Plenum (Y/N) | N |
---|
History
Update and Revision | Revision Number: 0.175 Revision Date: 03-08-2023 |
---|
Documentation
Product Bulletins
Catalogs
Guides
Technical Information
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|UPC|Length |
Variant_Options 7824R 0051000: |
7824R 0051000|Green, Dark|612825418252|1,000 ft |
Variant_Options 7824R 0052000: |
7824R 0052000|Green, Dark|612825443032|2,000 ft |
Variant_Options 7824R 0054000: |
7824R 0054000|Green, Dark|612825435013|4,000 ft |
Variant_Options 7824R 0051500: |
7824R 0051500|Green, Dark|612825418269|1,500 m |
Variant_Options 7824R 0051600: |
7824R 0051600|Green, Dark|612825352273|1,600 m |
Variant_Options 7824R 0055000: |
7824R 0055000|Green, Dark|612825436829|5,000 ft |
Variant_Options 7824R 005CUT: |
7824R 005CUT|Green, Dark|| |
Variant_Options 7824R 0053000: |
7824R 0053000|Green, Dark|612825378297|3,000 ft |