3-Channel SMPTE Stadium Cable, 6 Single Mode Fiber, 6 TC Conductor (19x30) 18 AWG and 6 TC Conductor (7x32) 24 AWG, FEP Insulation, Beldfoil Shield, PVDF Jacket, Plenum
Specifications
Specifications
Product Overview
| Suitable Applications | 3 Channel Composite Camera Cable |
|---|
Multiconductor
Multiconductor Conductor and Insulation
| Element | No. of Conductors | AWG | Stranding | Material | Nominal Conductor DCR | Insulation Material | Insulation Nominal Diameter |
|---|
| Blue Quad, Orange Quad, Green Quad | 6 | 24 | 7x32 | TC - Tinned Copper | 23.3 Ohm/1000ft Ohm/1000ft | FEP - Fluorinated Ethylene Propylene | 0.038 in |
| Blue Quad, Orange Quad, Green Quad | 6 | 18 | 19x30 | TC - Tinned Copper | 6.67 Ohm/1000ft | FEP - Fluorinated Ethylene Propylene | 0.064 in |
Multiconductor Color Chart
| Description | Color |
|---|
| Blue Quad - 24 AWG | Red |
| Blue Quad - 24 AWG | Gray |
| Blue Quad - 18 AWG | White |
| Blue Quad - 18 AWG | Black |
| Orange Quad - 24 AWG | Red |
| Orange Quad - 24 AWG | Gray |
| Orange Quad - 18 AWG | White |
| Orange Quad - 18 AWG | Black |
| Green Quad - 24 AWG | Red |
| Green Quad - 24 AWG | Gray |
| Green Quad - 18 AWG | White |
| Green Quad - 18 AWG | Black |
Multiconductor Inner Shield
| Layer | Inner Shield Type | Inner Shield Material | Inner Shield Coverage | Drainwire AWG | Drainwire Stranding | Drainwire Material | Drainwire Diameter | Drainwire Position |
|---|
| Blue Quad | Tape | Al/poly (Foil in) | 100 % | 24 | 7x32 | TC - Tinned Copper | 0.024 in | Under Shield Tape |
Multiconductor Inner Shield 02
| Layer | Inner Shield Type | Inner Shield Material | Inner Shield Coverage | Drainwire AWG | Drainwire Stranding | Drainwire Material | Drainwire Diameter | Drainwire Position |
|---|
| Orange Quad | Tape | Al/poly (Foil in) | 100.0 % | 24 | 7x32 | TC - Tinned Copper | 0.024 in | Under Shield Tape |
Multiconductor Inner Shield 03
| Layer | Inner Shield Type | Inner Shield Material | Inner Shield Coverage | Drainwire AWG | Drainwire Stranding | Drainwire Material | Drainwire Diameter | Drainwire Position |
|---|
| Green Quad | Tape | Al/poly (Foil in) | 100.0 % | 24 | 7x32 | TC - Tinned Copper | 0.024 in | Under Shield Tape |
Multiconductor Inner Jacket
| Element | Material | Nominal Diameter |
|---|
| Blue Quad | PVDF - Polyvinylidene Fluoride | 0.154 in |
| Orange Quad | PVDF - Polyvinylidene Fluoride | 0.154 in |
| Green Quad | PVDF - Polyvinylidene Fluoride | 0.154 in |
Multiconductor UL Voltage
| UL Description | UL Voltage Rating |
|---|
| 24 AWG | 300 V RMS |
| 18 AWG | 300 V RMS |
Fiber
Fiber Cable Construction
| Fiber Type | Fiber Count |
|---|
| OS2, G.657.A2 | 6 |
| Fiber Color Coding | TIA-598-D |
|---|
Buffer Specification
| Buffer Material | Buffer Diameter |
|---|
| PVC - Polyvinyl Chloride | 900 µm |
| Number of Active Subunits | 6 |
|---|
| Number of Subunit Positions | 6 |
|---|
| Fibers Per Subunit | 1 |
|---|
| Mode Field Diameter | 9.2 µm |
|---|
| Wavelength@Optical SM1 | 1310 nm, 1550 nm |
|---|
| Max. Attenuation at 1310 nm | 0.50 dB/km |
|---|
| Max. Attenuation at 1550 nm | 0.50 dB/km |
|---|
| Min Bend Radius/Minor Axis_CP_FB | 20x |
|---|
Overall Cable
| Conductor Material: | Tinned Copper |
|---|
Outer Jacket
| Jacket | PVDF |
|---|
| Nominal Diameter@OuterJacket1 1_CP_OV | 0.434 in |
|---|
| Operating Temperature Range | 0°C to 75°C |
|---|
| Installation Temperature Range | 0°C to 70°C |
|---|
| Storage Temperature Range | 0°C to 70°C |
|---|
| Min Bend Radius During Installation_OV | 20x |
|---|
| Max. Pull Tension | 800 N |
|---|
| Bulk Cable Weight | 170 lbs/1000ft |
|---|
Applicable Standards & Environmental Programs
| NEC/(UL) Compliance | CMP |
|---|
| CEC/C(UL) Compliance | CMP |
|---|
| Other Standards | SMPTE 311 |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| CA Prop 65 (CJ for Wire and Cable) | Yes |
|---|
| China RoHS II (GB/T 26572-2011) | Yes |
|---|
Suitability
Flame Test
| UL Flammability | NFPA 262 |
|---|
| CSA/C(UL) Flammability | FT6 |
|---|
Plenum/Non-Plenum
| Plenum (Y/N) | Yes |
|---|
| Non-Plenum Number | 7824R |
|---|
History
| Update and Revision | Revision Number: 0.21 Revision Date: 03-08-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Guides
Data Sheets