22 AWG solid tinned copper conductors, 6 twisted pairs, flame retardant polyolefin insulation, overall Beldfoil® shield (100% coverage), 22 AWG solid tinned copper drain wire, PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|
22 | Solid | TC - Tinned Copper | 0.0264 in | 6 |
Insulation
Color Chart
Number | Color |
---|
1 | White/Blue Stripe & Blue/White Stripe |
2 | White/Orange Stripe & Orange/White Stripe |
3 | White/Green Stripe & Green/White Stripe |
4 | White/Brown Stripe & Brown/White Stripe |
5 | White/Gray Stripe & Gray/White Stripe |
6 | Red/Blue Stripe & Blue/Red Stripe |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 22 | Solid |
Outer Jacket
Material | Nominal Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.38 in | Yes |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Outer Shield DCR |
---|
15.4 Ohm/1000ft | 3.6 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
16 pF/ft | 29 pF/ft |
Inductance
Nominal Inductance |
---|
0.21 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
100 Ohm |
High Frequency (Nominal/Typical)
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
66% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Max./Min. Input Impedance (unFitted) |
---|
0.772 MHz | 0.6 dB/100m | 50 dB | |
1 MHz | | | 100 +/- 15 Ohms |
Current
Max. Recommended Current [A] |
---|
3.5 Amps per Conductor at 20ºC |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Temperature Range
Installation Temperature Range | -20°C To +75°C |
---|
UL Temp Rating | 75°C |
---|
Storage Temperature Range | -20°C To +75°C |
---|
Operating Temperature Range | -20°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 70 lbs/1000ft |
---|
Max. Pull Tension | 93.6 lbs |
---|
Min. Bend Radius During Installation | 3.80 in |
---|
Min. Bend Radius/Minor Axis | 3.25 in |
---|
Standards
NEC/(UL) Compliance | MPR, CMR |
---|
CEC/C(UL) Compliance | CMR |
---|
Applicable Environmental and Other Programs
Environmental Space | Riser |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | Yes |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Aerial | No |
---|
Suitability - Burial | No |
---|
Suitability - Hazardous Locations | No |
---|
Suitability - Indoor | Yes |
---|
Suitability - Non-Halogenated | No |
---|
Suitability - Oil Resistance | No |
---|
Suitability - Outdoor | No |
---|
Suitability - Sunlight Resistance | No |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1666 Riser |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Product Notes
Footnote | C - CRATE REEL PUT-UP. |
---|