DNV GL, Shipboard, Category 6 Premise Horizontal Cable (250MHz), 4-Pair, 23 AWG solid bare copper conductors, F/UTP, Polyethylene insulation, Beldfoil® shield, AWG 26 solid tinned copper drainwire, LSZH jacket
Specifications
Specifications
Product Overview
Suitable Applications | Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10 Base - T, FDDI, ATM |
---|
Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
---|
Construction Details
Conductor
Element | Size | Stranding | Material | Number of Pairs | Number of Element |
---|
Individual Pair | 23 AWG | Solid | BC - Bare Copper | 4 | 8 |
Insulation
Element | Material | Nom. Insulation Diameter | Color Code |
---|
Individual Pair | PE - Polyethylene | 1.35 mm (0.0531 in) | White/Blue & Blue, White/Green & Green, White/Orange & Orange, White/Brown & Brown |
Cable Core
Description | Separator |
---|
4 pairs twisted together covered with a polyester foil | Center Member (Patented X-Spline®) |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 26 AWG (Solid) TC |
Table Notes | Aluminum facing outside in contact with drain wire |
---|
Outer Jacket
Material | Nom. Diameter |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 8.0 mm (0.31 in) |
Overall Cable Diameter (Nominal) | 8.0 mm (0.31 in) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Mutual Capacitance | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|
95 Ohm/km | 56 pF/m (17 pF/ft) | 160 pF/100m | 100 Ohm |
Delay
Max. Delay Skew | Nom. Velocity of Prop. |
---|
40 ns/100m | 68% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|
1 | 2.1 dB/100m | 75.3 | 72.3 | 73.2 | 70.2 | 70 | 67 | 20 | 40 | 35 |
4 | 3.8 dB/100m | 66.3 | 63.3 | 62.4 | 59.4 | 58 | 55 | 23 | 34 | 23 |
10 | 6 dB/100m | 60.3 | 57.3 | 54.3 | 51.3 | 50 | 47 | 25 | 30 | 15 |
16 | 7.6 dB/100m | 57.2 | 54.2 | 49.6 | 46.6 | 45.9 | 42.9 | 25 | 28 | 10.9 |
20 | 8.5 dB/100m | 55.8 | 52.8 | 47.3 | 44.3 | 44 | 41 | 25 | 27 | 9 |
31.2 | 10.7 dB/100m | 52.9 | 49.9 | 42.1 | 39.1 | 40.1 | 37.1 | 23.6 | 25.1 | 5.1 |
62.5 | 15.5 dB/100m | 48.4 | 45.4 | 32.9 | 29.9 | 34.1 | 31.1 | 21.5 | 22 | |
100 | 19.9 dB/100m | 45.3 | 42.3 | 25.4 | 22.4 | 30 | 27 | 20.1 | 20 | |
155 | 25.3 dB/100m | 42.4 | 39.4 | 17.1 | 14.1 | 26.2 | 23.2 | 18.8 | 18.1 | |
200 | 29.1 dB/100m | 40.8 | 37.8 | 11.6 | 8.6 | 24 | 21 | 18 | 17 | |
250 | 33 dB/100m | 39.3 | 36.3 | 6.3 | 3.3 | 22 | 19 | 17.3 | 16 | |
Table Notes | Limits below 4 MHz are for information only.
Reference standard: IEC 61156-5 |
---|
Transfer Impedance
Frequency | Max. Transfer Impedance |
---|
1 Mhz | Max. 50 mOhm/m |
10 Mhz | Max. 100 mOhm/m |
30 Mhz | Max. 200 mOhm/m |
100 Mhz | Max. 1000 mOhm/m |
Transfer Impedance Class | Grade 2 |
---|
Screening Class | Type II |
---|
Table Notes | Coupling Attenuation |
---|
Voltage
Mechanical Characteristics
Temperature
Operating | Installation |
---|
-30°C to +60°C | 0°C To +50°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
29 mm (1.1 in) | 58 mm |
Max. Pull Tension | 80 N (18 lbf) |
---|
Bulk Cable Weight | 50 kg/km |
---|
Standards and Compliance
Environmental Suitability | Indoor - Euroclass Dca |
---|
Flammability / Reaction to Fire | IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Dca-s2,d1,a1 |
---|
IEEE Compliance | PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
---|
Data Category | Category 6 |
---|
TIA/EIA Compliance | ANSI/TIA 568.2-D |
---|
Third Party Performance Verification | DNV GL certification |
---|
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61034-2 - Smoke Density Min Transmittance = 60% |
---|
CENELEC Compliance | EN 50173-1, Segregation class according EN50174-2 = c |
---|
European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
---|
European Directive Compliance | EU CE Mark |
---|
UK Regulation Compliance | UKCA Mark |
---|
Product Notes
Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. |
---|
History
Update and Revision | Revision Number: 0.102 Revision Date: 12-20-2022 |
---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets