Digital Audio Snake Cable, CM-Rated, 4-26 AWG tinned copper pairs, Datalene® insulation, individually shielded with Beldfoil® bonded to numbered/color-coded PVC jackets so both strip simultaneously, PVC jacket
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Pairs |
---|
26 | 7x34 | TC - Tinned Copper | 0.019 in | 4 |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Material | Material Trade Name | Nominal Diameter | Nominal Wall Thickness |
---|
PE - Polyethylene (Foam) | Datalene® | 0.054 in | 0.0175 in |
Color Chart
Number | Color |
---|
1 | Brown and Numbered 1 |
2 | Red and Numbered 2 |
3 | Orange and Numbered 3 |
4 | Yellow and Numbered 4 |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.019 in | 26 | Stranded |
Table Notes | Indiv. Foil tapes bonded to inner jacket |
---|
Inner Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
PVC - Polyvinyl Chloride | 0.136 in | 0.014 in |
Outer Shield
Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire Diameter | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | TC - Tinned Copper | 0.019 in | 26 | Stranded |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.399 in | 0.034 in | Yes |
Electrical Characteristics
Conductor DCR
Individual Pair Nominal Shield DCR | Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance |
---|
25.5 Ohm/1000ft | 37.3 Ohm/1000ft | 37.3 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
13 pF/ft | 25 pF/ft |
Inductance
Nominal Inductance |
---|
0.25 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
110 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
0.384 MHz | 0.84 dB/100ft |
0.7056 MHz | 1.14 dB/100ft |
0.768 MHz | 1.18 dB/100ft |
1.024 MHz | 1.34 dB/100ft |
1.4112 MHz | 1.5 dB/100ft |
1.536 MHz | 1.54 dB/100ft |
2.048 MHz | 1.69 dB/100ft |
2.8224 MHz | 1.86 dB/100ft |
3.072 MHz | 1.92 dB/100ft |
4.096 MHz | 2.14 dB/100ft |
5.6448 MHz | 2.4 dB/100ft |
6.144 MHz | 2.47 dB/100ft |
8.192 MHz | 2.75 dB/100ft |
11.2896 MHz | 3.09 dB/100ft |
12.288 MHz | 3.18 dB/100ft |
24.576 MHz | 4.2 dB/100ft |
Delay
Nominal Velocity of Propagation (VP) [%] |
---|
76% |
High Frequency
Frequency [MHz] |
---|
0.384 MHz |
0.7056 MHz |
0.768 MHz |
1.024 MHz |
1.4112 MHz |
1.536 MHz |
2.048 MHz |
2.8224 MHz |
3.072 MHz |
4.096 MHz |
5.6448 MHz |
6.144 MHz |
8.192 MHz |
11.2896 MHz |
12.288 MHz |
24.576 MHz |
Temperature Range
Operating Temperature Range | -30°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 52 lbs/1000ft |
---|
Max. Pull Tension | 45 lbs |
---|
Min. Bend Radius/Minor Axis | 4 in |
---|
Standards
NEC/(UL) Compliance | CM |
---|
CEC/C(UL) Compliance | CM |
---|
CPR Euroclass | Eca |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor (Not Riser or Plenum) |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
CSA Flammability | FT4 |
---|
IEC Flammability | IEC 60332-1-2 |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
Product Notes
Notes | Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |
---|
History
Update and Revision | Revision Number: 0.446 Revision Date: 12-20-2022 |
---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets