Broadband Coax, Series 6, 18 AWG Solid Bare Copper Conductor, FEP Insulation, Foil + 60% Aluminum Braid + Foil + 40% Aluminum Braid Shield, Flamarrest® Jacket, CMP
Specifications
Specifications
Product Overview
Suitable Applications | Broadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas |
---|
Construction Details
Conductor
Size | Stranding | Nom. Diameter | Material |
---|
18 AWG | Solid | 0.040 in | BC - Bare Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
FEP - Fluorinated Ethylene Propylene (Foam) | 0.170 in (4.32 mm) | White |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duobond® II | 100% |
2 | Braid | Aluminum | | 60% |
3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
4 | Braid | Aluminum | | 40% |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.248 in (6.30 mm) |
Overall Cable Diameter (Nominal) | 0.248 in (6.30 mm) |
---|
Electrical Characteristics
Return Loss
Frequency | Min. Structural Return Loss |
---|
5 - 1000 MHz | 20 dB |
1000 - 2250 MHz | 15 dB |
2250 - 3000 MHz | 10 dB |
Attenuation
Frequency | Nom. Attenuation |
---|
1 MHz | 0.3 dB/100ft |
10 MHz | 0.7 dB/100ft |
50 MHz | 1.6 dB/100ft |
100 MHz | 2.1 dB/100ft |
200 MHz | 2.9 dB/100ft |
400 MHz | 4.3 dB/100ft |
700 MHz | 6.1 dB/100ft |
750 MHz | 6.4 dB/100ft |
900 MHz | 7.1 dB/100ft |
1000 MHz | 8.2 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
6.4 Ohm/1000ft | 4.8 Ohm/1000ft (16 Ohm/km) | 16.3 pF/ft (53.5 pF/m) | 75 Ohm | 83% |
Voltage
UL Voltage Rating |
---|
300 V (CMP) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
75°C | -20°C to +75°C |
Bend Radius
Installation Min. |
---|
2.5 in (64 mm) |
Max. Pull Tension | 137 lbs (62.1 kg) |
---|
Bulk Cable Weight | 39 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor - Plenum, Indoor |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | NFPA 262 |
---|
CEC / C(UL) Compliance | CMP |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Non-Plenum Number | 7916A |
---|
History
Update and Revision | Revision Number: 0.472 Revision Date: 04-13-2023 |
---|
Documentation
Product Bulletins
Brochures
Compliance Documentation
Data Sheets