Industrial Ethernet Cat 5e, 2 Bonded-Pair 24AWG (Solid) Bare Copper, PO Insulation, Overall Beldfoil® Shield, PVC Outer Jacket, CMR SUN RES OIL RES
Specifications
Specifications
Product Overview
| Suitable Applications | harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
|---|
Construction Details
Conductor
| Element | Size | Stranding | Material | Number of Pairs | Number of Element |
|---|
| Pair(s) | 24 AWG | Solid | BC - Bare Copper | 2 | 2 |
Insulation
| Material | Color Code |
|---|
| PO - Polyolefin | White/Orange Stripe & Orange, White/Green Stripe & Green |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
Outer Jacket
| Material | Nom. Diameter | Ripcord |
|---|
| PVC - Polyvinyl Chloride | 0.235 in (5.97 mm) | No |
| Overall Cable Diameter (Nominal) | 0.235 in (5.97 mm) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Capacitance Unbalance |
|---|
| 93.8 Ohm/km (28.6 Ohm/1000ft) | 90 pF/100m |
Delay
| Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 552 ns/100m | 45 ns/100m | 70% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. SRL (Structural Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] |
|---|
| 1 | 2.1 dB/100m | 65.3 | 62.3 | 63.2 | 60 | 63.8 | 60.8 | 23 | 23 | 100 ± 20.2 | 105 ± 10 |
| 4 | 4.0 dB/100m | 56.3 | 53.3 | 56.3 | 49 | 51.7 | 48.7 | 23 | 23 | 100 ± 14.2 | 100 ± 10 |
| 8 | 5.6 dB/100m | 51.8 | 48.8 | 46.2 | 43 | 45.7 | 42.7 | 23 | 24.5 | 100 ± 11.3 | 100 ± 10 |
| 10 | 6.3 dB/100m | 50.3 | 47.3 | 43.9 | 41 | 43.8 | 40.8 | 25 | 25 | 100 ± 11.3 | 100 ± 10 |
| 16 | 8.0 dB/100m | 47.3 | 44.3 | 35.2 | 36 | 39.7 | 36.7 | 25 | 25 | 100 ± 11.3 | 100 ± 10 |
| 20 | 9.0 dB/100m | 45.8 | 42.8 | 36.5 | 33.5 | 37.7 | 34.7 | 25 | 25 | 100 ± 11.3 | 100 ± 10 |
| 25 | 10.1 dB/100m | 44.3 | 41.3 | 34.2 | 30.9 | 35.8 | 32.8 | 25.5 | 24.3 | 100 ± 11.3 | 100 ± 10 |
| 31.25 | 11.4 dB/100m | 42.9 | 39.9 | 31.3 | 28 | 33.9 | 30.9 | 23.6 | 23.6 | 100 ± 13.2 | 100 ± 10 |
| 62.5 | 16.5 dB/100m | 38.4 | 35.4 | 21.6 | 19 | 27.8 | 24.8 | 21.5 | 21.5 | 100 ± 16.9 | 100 ± 10 |
| 100 | 21.3 dB/100m | 35.3 | 32.3 | 17.1 | 11 | 23.8 | 20.8 | 20.1 | 20.1 | 100 ± 20.0 | 100 ± 10 |
| 155 | 28.1 dB/100m | 32.5 | 29.5 | 4.4 | 1.4 | 19.9 | 16.9 | 15.8 | | 100 ± 25.0 | 100 ± 15 |
| 200 | 32 dB/100m | 30.8 | 27.8 | 4 | 1 | 17.7 | 14.7 | 15 | | 100 ± 25.0 | 100 ± 15 |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMR) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating | Installation | Storage |
|---|
| 60°C | -40°C To +80°C | -25°C To +60°C | -40°C To +80°C |
Bend Radius
| Stationary Min. |
|---|
| 2.560 in (65.02 mm) |
| Max. Pull Tension | 55 lbs (25 kg) |
|---|
| Bulk Cable Weight | 31 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance |
|---|
| Flammability / Reaction to Fire | UL 1685 (FT4 Loading), FT4, IEEE 1202 Vertical Tray Flame Test, IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| NEC / UL Compliance | Article 800, CMR |
|---|
| CEC / C(UL) Compliance | CMR |
|---|
| NEMA Compliance | NEMA WC-63.1 |
|---|
| Data Category | Category 5e |
|---|
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
|---|
| ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-5 |
|---|
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
Product Notes
| Notes | Operating Temperature subject to length de-rating. Cable passes -40C Cold Bend per UL 1581. Limits below 4 MHz are for information only. |
|---|
History
| Update and Revision | Revision Number: 0.565 Revision Date: 01-20-2023 |
|---|
Documentation
Product Bulletins
Warranties
Compliance Documentation
Data Sheets