Conductor
Element | Size | Stranding | Material | Number of Element |
---|
Quad(s) | 22 AWG | 7x30 | TC - Tinned Copper | 1 |
Insulation
Material | Color Code |
---|
PO - Polyolefin | White, Blue, Yellow, Orange |
Inner Jacket
Material | Nom. Diameter |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.164 in (4.17 mm) |
Outer Shield
Shield Type | Material | Coverage |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Braid | Tinned Copper (TC) | 85% |
Outer Jacket
Material | Nom. Diameter | Ripcord |
---|
PVC - Polyvinyl Chloride | 0.272 in (6.91 mm) | No |
Overall Cable Diameter (Nominal) | 0.272 in (6.91 mm) |
---|
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance |
---|
57 Ohm/km (17 Ohm/1000ft) | 150 pF/ft |
Delay
Max. Delay | Nom. Velocity of Prop. |
---|
552 ns/100m | 70% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) [Ohm] | Max./Min. Fitted Impedance [Ohm] |
---|
1 | 2.1 dB/100m | 65.3 | 62.3 | 63.2 | 63.8 | 60.8 | 23 | 100 ± 20.2 | 105 ±10 |
4 | 4.0 dB/100m | 56.3 | 53.3 | 56.3 | 51.7 | 48.7 | 23 | 100 ± 14.2 | 100 ±10 |
8 | 5.6 dB/100m | 51.8 | 48.8 | 46.2 | 45.7 | 42.7 | 23 | 100 ± 11.3 | 100 ±10 |
10 | 6.3 dB/100m | 50.3 | 47.3 | 43.9 | 43.8 | 40.8 | 25 | 100 ± 11.3 | 100 ±10 |
16 | 8.0 dB/100m | 47.3 | 44.3 | 35.2 | 39.7 | 36.7 | 25 | 100 ± 11.3 | 100 ±10 |
20 | 9.0 dB/100m | 45.8 | 42.8 | 36.5 | 37.7 | 34.7 | 25 | 100 ± 11.3 | 100 ±10 |
25 | 10.1 dB/100m | 44.3 | 41.3 | 34.2 | 35.8 | 32.8 | 25.5 | 100 ± 11.3 | 100 ±10 |
31.25 | 11.4 dB/100m | 42.9 | 39.9 | 31.3 | 33.9 | 30.9 | 23.6 | 100 ± 13.2 | 100 ±10 |
62.5 | 16.5 dB/100m | 38.4 | 35.4 | 21.6 | 27.8 | 24.8 | 21.5 | 100 ± 16.9 | 100 ±10 |
100 | 21.3 dB/100m | 35.3 | 32.3 | 17.1 | 23.8 | 20.8 | 20.1 | 100 ± 20.0 | 100 ±10 |
Voltage
UL Voltage Rating |
---|
300 V (CMG, CMX-Outdoor), 600 V (AWM 21047) |
Mechanical Characteristics
Temperature
UL Temperature | Operating | Installation | Storage |
---|
60°C | -40°C To +80°C | -20°C To +60°C | -40°C To +80°C |
Bend Radius
Stationary Min. |
---|
2.560 in (65.02 mm) |
Max. Pull Tension | 55 lbs (25 kg) |
---|
Bulk Cable Weight | 43 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance |
---|
Flammability / Reaction to Fire | UL 1685 (UL Loading), FT4, IEEE 1202 Vertical Tray Flame Test, IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 800, CMG, CMX-Outdoor, ITC, PLTC |
---|
AWM Compliance | AWM 21047 |
---|
CEC / C(UL) Compliance | CMX-Outdoor;CMG |
---|
NEMA Compliance | NEMA WC-63.1 |
---|
Data Category | Category 5e |
---|
TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
---|
ISO/IEC Compliance | ISO/IEC 11801-1, IEC 61156-6 |
---|
European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Product Notes
Notes | Operating Temperature subject to length de-rating. Cable passes -40C Cold Bend per UL 1581. Limits below 4 MHz are for information only. |
---|
History
Update and Revision | Revision Number: 0.428 Revision Date: 04-14-2023 |
---|
Documentation
Product Bulletins
Warranties
Compliance Documentation