Broadband Coax, Series 11, 14 AWG Solid Bare Copper Covered Steel Conductor, FEP Insulation, Foil + 60% Aluminum Braid + Foil + 40% Aluminum Braid Shield, PVDF Jacket, CMP
Specifications
Specifications
Product Overview
| Suitable Applications | Broadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas | 
|---|
Construction Details
Conductor
| Number of Element | Size | Stranding | Nom. Diameter | Material | 
|---|
| 1 | 14 AWG | Solid | 0.064 in | BCCS - Bare Copper Covered Steel | 
Insulation
| Material | Nom. Insulation Diameter | Color Code | 
|---|
| FEP - Fluorinated Ethylene Propylene (Foam) | 0.274 in (6.96 mm) | White | 
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage | 
|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% | 
| 2 | Braid | Aluminum |  | 60% | 
| 3 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% | 
| 4 | Braid | Aluminum |  | 40% | 
Outer Jacket
| Material | Nom. Diameter | 
|---|
| PVDF - Polyvinylidene Fluoride | 0.372 in (9.45 mm) | 
| Overall Cable Diameter (Nominal) | 0.372 in (9.45 mm) | 
|---|
Electrical Characteristics
Return Loss
| Frequency | Min. Structural Return Loss | 
|---|
| 5 - 1000 MHz | 20 dB | 
| 1000 - 2250 MHz | 15 dB | 
| 2250 - 3000 MHz | 10 dB | 
Attenuation
| Frequency | Nom. Attenuation | 
|---|
| 1 MHz | 0.2 dB/100ft | 
| 10 MHz | 0.5 dB/100ft | 
| 50 MHz | 0.9 dB/100ft | 
| 100 MHz | 1.3 dB/100ft | 
| 200 MHz | 1.9 dB/100ft | 
| 400 MHz | 2.8 dB/100ft | 
| 700 MHz | 3.9 dB/100ft | 
| 750 MHz | 4.3 dB/100ft | 
| 900 MHz | 4.7 dB/100ft | 
| 1000 MHz | 5.0 dB/100ft | 
| 1450 MHz | 6.7 dB/100ft | 
| 1800 MHz | 7.7 dB/100ft | 
| 2250 MHz | 8.5 dB/100ft | 
| 3000 MHz | 9.9 dB/100ft | 
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance 
        Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. | 
|---|
| 11 Ohm/1000ft (36 Ohm/km) | 3 Ohm/1000ft (9.8 Ohm/km) | 16.3 pF/ft (53.5 pF/m) | 75 Ohm | 83% | 
Voltage
| UL Voltage Rating | Voltage Rating | 
|---|
| 300 V RMS | 300 V RMS | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 150°C | -20°C To +150°C | 
Bend Radius
| Stationary Min. | Installation Min. | 
|---|
| 3.75 in (95.3 mm) | 3.75 in (95.3 mm) | 
| Max. Pull Tension | 260 lbs (120 kg) | 
|---|
| Bulk Cable Weight | 63 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor | 
|---|
| Flammability / Reaction to Fire | NFPA 262, FT6 | 
|---|
| NEC / UL Compliance | Article 800, CATVP, CMP | 
|---|
| CEC / C(UL) Compliance | CMP | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
| Non-Plenum Number | 7999A | 
|---|
Product Notes
| Notes | PF_7999AP 1)# Elements@Conductor1:-In Stibo it was Blank and now changed to 1. 2)Size@Conductor1 :-In Stibo it was 14 now changed to 14AWG. 3)Color@Color Chart1 01 :- In stibo it was Blank now Changed to White. 4)Material@OuterShield1 1 - In stibo it is Tri-Laminate (Alum+Poly+Alum) But in BPCS (Heat fusible+ Alum+ Poly+Alum 5)Material@OuterShield1 3 - In stibo it is Tri-Laminate (Alum+Poly+Alum) But in BPCS (Alum+ Poly+Alum+microcapsulated mineral oil. 6)Cable Diameter (Nominal)- In Stibo it was Blank Now Changed to 0.372 in. 7)Bulk Cable Weight - In stibo it was 62 lbs/1000 ft Now changed to 63 lbs/1000 ft. | 
|---|
History
| Update and Revision | Revision Number: 0.472    Revision Date: 05-03-2023 | 
|---|
Documentation
Product Bulletins
Brochures
Compliance Documentation
Data Sheets