Belden
8105 - RS-232/422 Low Cap, #24-5pr, FPO, O/A Foil+Braid, PVC Jkt, CM, 100Ω
- SKU:
- 8105
- Shipping:
- Calculated at Checkout
Description
Computer EIA RS-232/422 Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + tinned copper braid shield (65% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | rs-232 extended distance applications; rs-422 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; panel wiring |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|---|---|---|---|
| Pair(s) | 5 | 24 AWG | 7x32 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|---|
| Pair(s) | PE - Polyethylene (Foam) | 0.013 in (0.33 mm) | 0.049 in (1.2 mm) | Western Electric Standard |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
| Braid | Tinned Copper (TC) | 65% |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PVC - Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.303 in (7.70 mm) |
| Overall Cable Diameter (Nominal) | 0.303 in (7.70 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
|---|---|---|---|---|---|---|
| Pair(s) | 24 Ohm/1000ft | 12.5 pF/ft (41.0 pF/m) | 22 pF/ft (72 pF/m) | 100 Ohm | 78% | 1.5 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CM), 30 V (UL AWM 2919) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 80°C | -30°C to +80°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 3.0 in (76 mm) | 3.0 in (76 mm) |
| Max. Pull Tension | 63 lbs (29 kg) |
|---|---|
| Bulk Cable Weight | 43 lbs/1000ft |
Standards and Compliance
| Environmental Suitability | Indoor (Not Riser or Plenum), Indoor |
|---|---|
| Flammability / Reaction to Fire | UL 1685 FT4 Loading, IEC 60332-1-2 |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | Article 800, CM |
| AWM Compliance | AWM 2919 |
| CEC / C(UL) Compliance | CM |
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Plenum Number | 88105 |
Product Notes
| Notes | Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |
|---|
History
| Update and Revision | Revision Number: 0.551 Revision Date: 01-20-2023 |
|---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC/EAN |
Variant_Options 8105.0030: |
8105.0030|Chrome|Reel|30 m|8719605017802 |
Variant_Options 8105 060100: |
8105 060100|Chrome|Reel|100 ft|612825194880 |
Variant_Options 8105.01152: |
8105.01152|Chrome|Reel|152 m|8719605017826 |
Variant_Options 8105.00305: |
8105.00305|Chrome|Reel|305 m|8719605017819 |
Variant_Options 8105 060500: |
8105 060500|Chrome|Reel|500 ft|612825194903 |
Variant_Options 8105 0601000: |
8105 0601000|Chrome|Reel|1,000 ft|612825194897 |
Variant_Options 8105 0605000: |
8105 0605000|Chrome|Reel|5,000 ft|612825194910 |