Belden

8125 - RS232/422 Low Cap, #24-25pr, FPO, O/A Foil+Braid, PVC Jkt, CMG, 100Ω

(No reviews yet) Write a Review
SKU:
8125
Shipping:
Calculated at Checkout
$0.00

Description

Computer EIA RS-232/422 Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + tinned copper braid shield (65% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.

Specifications

Specifications

Product Overview

Suitable Applicationsrs-232 extended distance applications; rs-422 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; panel wiring

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)2524 AWG7x32TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Pair(s)PE - Polyethylene (Foam)0.013 in (0.33 mm)0.049 in (1.2 mm)Western Electric Standard

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%24 AWG (7x32) TC
BraidTinned Copper (TC)65%

Outer Jacket

MaterialNom. ThicknessNom. Diameter
PVC - Polyvinyl Chloride0.050 in (1.3 mm)0.632 in (16.1 mm)
Overall Cable Diameter (Nominal)0.632 in (16.1 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRMax. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Pair(s)24 Ohm/1000ft7.4 Ohm/1000ft12.5 pF/ft (41.0 pF/m)22 pF/ft (72 pF/m)100 Ohm78%1 Amp per Conductor at 25ºC

Voltage

UL Voltage Rating
300 V (CM), 30 V (UL AWM 2919)

Mechanical Characteristics

Temperature

UL TemperatureOperating
80°C-30°C to +80°C

Bend Radius

Stationary Min.Installation Min.
6.3 in (160 mm)6.3 in (160 mm)
Max. Pull Tension355 lbs (161 kg)
Bulk Cable Weight175 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor
Flammability / Reaction to FireUL 1685 FT4 Loading
NEC / UL ComplianceArticle 800, CM
AWM ComplianceAWM 2919
CEC / C(UL) ComplianceCM
European Directive ComplianceEU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Plenum Number88125

Product Notes

NotesDatalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight.

History

Update and RevisionRevision Number: 0.450 Revision Date: 01-20-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 8125 060100:
8125 060100|Chrome|Reel|100 ft|612825195153
Variant_Options 8125 060500:
8125 060500|Chrome|Reel|500 ft|612825195177
Variant_Options 8125 0601000:
8125 0601000|Chrome|Reel|1,000 ft|612825195160
View AllClose