Twinax, 77 ohm, 24 AWG stranded (19x36) .024" silver-coated high-strength copper alloy conductor, TFE insulation, silver-coated high strength copper alloy braid shield (93% coverage), PFA jacket, commercial non-QPL product
Specifications
Specifications
Product Overview
| Suitable Applications | Harsh Environment, IIoT, Factory or Process Automation, Video, Audio, Data Communication, etc. |
|---|
Construction Details
Conductor
| Number of Element | Size | Stranding | Nom. Diameter | Material |
|---|
| 2 | 24 AWG | 19x36 | 0.024 in | SHSCA - Silver Coated High Strength Copper Alloy |
Insulation
| Material | Nom. Insulation Diameter | Color Code |
|---|
| PTFE - Polytetrafluoroethylene | 0.042 in (1.1 mm) | White & Blue |
Outer Shield
| Outer Shield Type | Material | Coverage |
|---|
| Braid | Silvered High Strength Copper Alloy (SHSCA) | 93% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| PFA - Perfluoroalkoxy | 0.129 in (3.28 mm) |
Electrical Characteristics
Attenuation
| Frequency | Nom. Attenuation |
|---|
| 1 MHz | 1.2 dB/100ft |
| 10 MHz | 4.0 dB/100ft |
| 50 MHz | 9.2 dB/100ft |
| 100 MHz | 13.0 dB/100ft |
| 200 MHz | 18.4 dB/100ft |
| 400 MHz | 26.1 dB/100ft |
| 700 MHz | 34.6 dB/100ft |
| 900 MHz | 39.3 dB/100ft |
| 1000 MHz | 41.4 dB/100ft |
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. | Max. Delay Skew |
|---|
| 24.5 Ohm/1000ft | 7.3 Ohm/1000ft (24 Ohm/km) | 24.0 pF/ft (78.7 pF/m) | 77 Ohm | 70% | 70 ns/100m |
Voltage
| UL Voltage Rating |
|---|
| 150 V RMS |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 200°C | -55°C To +200°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 1.29 in (32.8 mm) | 1.29 in (32.8 mm) |
| Max. Pull Tension | 51 lbs (23 kg) |
|---|
| Bulk Cable Weight | 15 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Indoor |
|---|
| Flammability / Reaction to Fire | NFPA 262 (UL 910), IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
|---|
| NEC / UL Compliance | Article 725, CL2P |
|---|
| Military Compliance | Commercial, non-QPL product (M17/176-00002, MIL-STD-1553 Data Bus Cable) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
Product Notes
| Notes | PF_81553 1)# Elements@Conductor1:-In Stibo it was Blank and now changed to 2. 2)Size@Conductor1 :-In Stibo it was 24 now changed to 24AWG. 3)Color@Color Chart1 01 :- In stibo it was Blank now Changed to White & Blue. 4)Cable Diameter (Nominal)- In Stibo it was Blank Now Changed to 0.129 in. 5)Coverage@OuterShield1 2 - in stibo it was 93% Now changed to 90%. |
|---|
History
| Update and Revision | Revision Number: 0.469 Revision Date: 05-25-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets