18 AWG solid .040" bare copper conductor, plenum, foam FEP insulation, Duofoil®; tinned copper braid shield (65% coverage), Flamarrest® jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
18 | Solid | BC - Bare Copper | 0.04 in | 1 |
Insulation
Material | Nominal Diameter |
---|
FEP - Fluorinated Ethylene Propylene (Foam) | 0.17 in |
Outer Shield
Type | Layer | Material | Material Trade Name | Coverage [%] |
---|
Tape | 1 | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
Braid | 2 | Tinned Copper (TC) | | 65% |
Outer Jacket
Material | Material Trade Name | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | Flamarrest® | 0.222 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
6.4 Ohm/1000ft | 6.4 Ohm/1000ft | 5.1 Ohm/1000ft | 5.1 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
16.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.09 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
Return Loss
Frequency [MHz] | Minimum Return (RL) |
---|
5-450 MHz | 23 dB |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.3 dB/100ft |
10 MHz | 0.7 dB/100ft |
50 MHz | 1.6 dB/100ft |
100 MHz | 2.2 dB/100ft |
200 MHz | 3 dB/100ft |
400 MHz | 4.6 dB/100ft |
700 MHz | 6.6 dB/100ft |
900 MHz | 7.7 dB/100ft |
1000 MHz | 8.2 dB/100ft |
1500 MHz | 10.7 dB/100ft |
1600 MHz | 11 dB/100ft |
2000 MHz | 12.9 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.24 ns/ft | 82% |
Voltage
Non-UL Voltage Rating | UL Voltage Rating |
---|
300 V RMS | 300 V RMS |
Temperature Range
Non-UL Temp Rating | 75°C |
---|
UL Temp Rating | 75°C |
---|
Operating Temperature Range | -20°C To +75°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 28 lbs/1000ft |
---|
Max. Pull Tension | 45 lbs |
---|
Min. Bend Radius/Minor Axis | 2.25 in |
---|
Standards
NEC/(UL) Compliance | CMP |
---|
CEC/C(UL) Compliance | CMP |
---|
RG Type | 6 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Plenum |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Flammability, LS0H, Toxicity Testing
UL Flammability | NFPA 262 |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Non-Plenum Number | 9248 |
---|
Footnote | C - CRATE REEL PUT-UP. |
---|
History
Update and Revision | Revision Number: 0.354 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Catalogs
Tools
Data Sheets