Triax, RG11, 14 AWG Solid Bare Copper Conductor, PE Insulation, 95% Bare Copper Braid Shield, PVC Insulation, 80% Bare Copper Braid Shield, PVC Jacket, CMR
Specifications
Specifications
Product Overview
Suitable Applications | Analog Video; Interconnect camera to CCU (camera control unit) |
---|
Construction Details
Conductor
Size | Stranding | Nom. Diameter | Material |
---|
14 AWG | Solid | 0.064 in | BC - Bare Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
PE - Polyethylene (Foam) | 0.285 in (7.24 mm) | White |
Inner Shield
Layer | Shield Type | Material | Coverage |
---|
1 | Braid | Bare Copper (BC) | 95% |
Inner Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.365 in (9.27 mm) |
Outer Shield
Layer | Outer Shield Type | Material | Coverage |
---|
1 | Braid | Bare Copper (BC) | 80% |
Outer Jacket
Material | Nom. Diameter |
---|
PVC - Polyvinyl Chloride | 0.475 in (12.1 mm) |
Overall Cable Diameter (Nominal) | 0.475 in (12.1 mm) |
---|
Electrical Characteristics
Return Loss
Frequency | Min. Return Loss |
---|
5 - 850 MHz | 21 dB |
850 - 4500 MHz | 15 dB |
Attenuation
Frequency | Nom. Attenuation |
---|
1 MHz | 0.14 dB/100ft |
3.6 MHz | 0.30 dB/100ft |
10 MHz | 0.40 dB/100ft |
71.5 MHz | 1.10 dB/100ft |
135 MHz | 1.60 dB/100ft |
270 MHz | 2.30 dB/100ft |
360 MHz | 2.60 dB/100ft |
540 MHz | 3.30 dB/100ft |
720 MHz | 3.80 dB/100ft |
750 MHz | 4.00 dB/100ft |
1000 MHz | 4.60 dB/100ft |
1500 MHz | 5.90 dB/100ft |
2250 MHz | 7.40 dB/100ft |
3000 MHz | 9.00 dB/100ft |
4500 MHz | 12.50 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Outer Shield DCR | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|
2.6 Ohm/1000ft | 1.7 Ohm/1000ft (5.6 Ohm/km) | 1.5 Ohm/1000ft (4.9 Ohm/km) | 16.1 pF/ft (52.8 pF/m) | 75 Ohm | 84% |
Voltage
UL Voltage Rating |
---|
300 V (CMR, CMG) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
60°C | -40°C to +80°C |
Bend Radius
Installation Min. |
---|
5.0 in (130 mm) |
Max. Pull Tension | 170 lbs (77 kg) |
---|
Bulk Cable Weight | 125 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor/Outdoor, Indoor, Aerial - Black only, When supported by messenger wire |
---|
Sustainability | CA Prop 65 |
---|
Flammability / Reaction to Fire | UL1666 Vertical Shaft |
---|
NEC / UL Compliance | CMR |
---|
CEC / C(UL) Compliance | CMG |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Plenum Number | 8233P |
---|
History
Update and Revision | Revision Number: 0.494 Revision Date: 04-13-2023 |
---|