23 AWG solid .023" bare copper-covered steel conductor, flame-retardant semi-foam Polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 23 | Solid | BCCS - Bare Copper Covered Steel | 0.023 in | 1 |
Insulation
| Material | Nominal Diameter |
|---|
| PE - Polyethylene (Foam) | 0.146 in |
Outer Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Bare Copper (BC) | 95% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.242 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 49 Ohm/1000ft | 49 Ohm/1000ft | 2.6 Ohm/1000ft | 2.6 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 20.5 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.112 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 75 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.6 dB/100ft |
| 5 MHz | 0.9 dB/100ft |
| 10 MHz | 1.1 dB/100ft |
| 50 MHz | 2.4 dB/100ft |
| 100 MHz | 3.4 dB/100ft |
| 200 MHz | 4.9 dB/100ft |
| 400 MHz | 7 dB/100ft |
| 700 MHz | 10.1 dB/100ft |
| 900 MHz | 11.7 dB/100ft |
| 1000 MHz | 13.2 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.54 ns/ft | 66% |
Voltage
| UL Voltage Rating | Voltage Rating [V] |
|---|
| 300 V RMS | 30 V RMS |
| Electrical Characteristics Notes | 30 V RMS (UL AWM Style 1354); 300 V RMS |
|---|
Temperature Range
| UL Temp Rating | 75°C |
|---|
| Operating Temperature Range | -40°C To +75°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 39 lbs/1000ft |
|---|
| Max. Pull Tension | 74 lbs |
|---|
| Min. Bend Radius/Minor Axis | 2.5 in |
|---|
Standards
| NEC/(UL) Compliance | CMG |
|---|
| CEC/C(UL) Compliance | CMG |
|---|
| UL AWM Style Compliance | AWM 1354 (30 V 75°C) |
|---|
| RG Type | 59 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | No |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 FT4 Loading |
|---|
| UL voltage rating | 300 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History
| Update and Revision | Revision Number: 0.339 Revision Date: 11-09-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Data Sheets