23 AWG solid .023" bare copper conductor, polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | Nominal Diameter | No. of Coax |
---|
23 | Solid | BC - Bare Copper | 0.023 in | 1 |
Insulation
Material | Nominal Diameter |
---|
PE - Polyethylene | 0.146 in |
Outer Shield
Type | Material | Coverage [%] |
---|
Braid | Bare Copper (BC) | 95% |
Outer Jacket
Material | Nominal Diameter |
---|
PVC - Polyvinyl Chloride | 0.242 in |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
---|
20.4 Ohm/1000ft | 20.4 Ohm/1000ft | 2.9 Ohm/1000ft | 2.9 Ohm/1000ft |
Capacitance
Nom. Capacitance Conductor to Shield |
---|
20.5 pF/ft |
Inductance
Nominal Inductance |
---|
0.131 µH/ft |
Impedance
Nominal Characteristic Impedance |
---|
75 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] | Nom. Insertion Loss |
---|
1 MHz | 0.4 dB/100ft |
10 MHz | 1.1 dB/100ft |
50 MHz | 2.4 dB/100ft |
100 MHz | 3.4 dB/100ft |
200 MHz | 4.9 dB/100ft |
400 MHz | 7 dB/100ft |
700 MHz | 9.7 dB/100ft |
900 MHz | 11.1 dB/100ft |
1000 MHz | 12 dB/100ft |
Delay
Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|
1.54 ns/ft | 66% |
Power Rating
Frequency [MHz] | Max. Power Rating [W] |
---|
50 MHz | 470 W |
100 MHz | 310 W |
300 MHz | 160 W |
500 MHz | 115 W |
1,000 MHz | 76 W |
Voltage
Non-UL Voltage Rating | UL Voltage Rating | Voltage Rating [V] |
---|
1700 V RMS | 300 V RMS | 30 V RMS |
Electrical Characteristics Notes | 30 V RMS (UL AWM Style 1354) |
---|
Temperature Range
UL Temp Rating | 80°C |
---|
Operating Temperature Range | -20°C To +80°C |
---|
Mechanical Characteristics
Bulk Cable Weight | 34 lbs/1000ft |
---|
Max. Pull Tension | 62 lbs |
---|
Min. Bend Radius/Minor Axis | 2.5 in |
---|
Standards
NEC/(UL) Compliance | CM |
---|
CEC/C(UL) Compliance | CM |
---|
UL AWM Style Compliance | AWM 1354 (30 V 80°C) |
---|
CPR Euroclass | Eca |
---|
RG Type | 59 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor (Not Riser or Plenum) |
---|
EU Directive 2000/53/EC (ELV) | Yes |
---|
EU Directive 2003/11/EC (BFR) | Yes |
---|
EU Directive 2011/65/EU (RoHS 2) | Yes |
---|
EU Directive 2012/19/EU (WEEE) | Yes |
---|
EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | No |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Outdoor | Yes |
---|
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1685 UL Loading |
---|
UL voltage rating | 300 V RMS |
---|
Plenum/Non-Plenum
Related Part Numbers
Footnote | C - CRATE REEL PUT-UP. |
---|
Product Notes
Notes | RG-59/U Type standard Analog Video Coax. CM Rated Version of 8241. |
---|
History
Update and Revision | Revision Number: 0.381 Revision Date: 12-19-2022 |
---|
Documentation
Product Bulletins
Catalogs
Data Sheets