Computer EIA RS-232 Cable, 1-Pair, 24 AWG stranded (7x32) tinned copper conductors, FEP insulation, overall Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, Flamarrest® jacket, plenum rated
Specifications
Specifications
Product Overview
| Suitable Applications | indoor plenum applications; RS-232 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; panel wiring |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Pair(s) | 1 | 24 AWG | 7x32 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Pair(s) | FEP - Fluorinated Ethylene Propylene | 0.006 in (0.15 mm) | 0.036 in (0.91 mm) | Black & Red |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.015 in (0.38 mm) | 0.108 in (2.74 mm) |
| Overall Cable Diameter (Nominal) | 0.108 in (2.74 mm) |
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
|---|
| Pair(s) | 24.1 Ohm/1000ft | 31 pF/ft (100 pF/m) | 59 pF/ft (190 pF/m) | 2.2 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 60°C | 0°C to +60°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 1.08 in (27.4 mm) | 1.08 in (27.4 mm) |
| Max. Pull Tension | 16 lbs (7.3 kg) |
|---|
| Bulk Cable Weight | 8 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum) |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| NEC / UL Compliance | Article 800, CMP |
|---|
| CEC / C(UL) Compliance | CMP |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
| Plenum Number | 88641 |
|---|
| Non-Plenum Number | 8641 |
|---|
History
| Update and Revision | Revision Number: 0.535 Revision Date: 01-20-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets