Type KX Thermocouple, 1 Pair 20AWG (Solid) Chromel+Alumel, FEP Insulation Yel, Red Color Code, Yellow FEP Outer Jacket, CL3P 200C PLTC SUN RES
Specifications
Specifications
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 1 | 20 AWG | Solid | Chromel & Alumel |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Pair(s) | FEP - Fluorinated Ethylene Propylene | 0.01 in (0.25 mm) | 0.052 in (1.3 mm) | Yellow, Red |
Outer Shield
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
FEP - Fluorinated Ethylene Propylene | 0.012 in (0.30 mm) | 0.076 x 0.128 in |
Overall Cable Diameter (Nominal) | 0.076 x 0.128 in |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR |
---|
420 Ohm/1000ft |
169 Ohm/1000ft (554 Ohm/km) |
Voltage
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
200°C | -70°C to +200°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
0.76 in (19 mm) | 0.76 in |
Max. Pull Tension | 575 lbs (261 kg) |
---|
Bulk Cable Weight | 12 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
---|
Flammability / Reaction to Fire | NFPA 262 (UL 910) |
---|
NEC / UL Compliance | Article 725 |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Other Standard Compliance(s) | ISA MC 96.1-1982 Type KX |
---|
Product Notes
Notes | Chromel & Alumel = ""Chromel and Alumel are Hoskins Manufacturing Company trademarks."" |
---|
History
Update and Revision | Revision Number: 0.393 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Catalogs
Compliance Documentation
Data Sheets