Mic, 20 AWG stranded (19x32) high-conductivity TC conductors, cabled, polyethylene insulation, rayon braid, TC braid shield (85% coverage), PVC jacket.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Conductors |
|---|
| 20 | 19x32 | TC - Tinned Copper (High Conductivity) | 0.037 in | 5 |
Insulation
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| PE - Polyethylene | 0.069 in | 0.016 in |
Color Chart
| Number | Color |
|---|
| 1 | Black |
| 2 | Clear |
| 3 | Green |
| 4 | Red |
| 5 | Blue |
Outer Shield
| Type | Material | Coverage [%] |
|---|
| Braid | Rayon® | 85% |
| Braid | Tinned Copper (TC) | 85% |
Outer Jacket
| Material | Nominal Diameter | Min. Wall Thickness | Nominal Wall Thickness | Separator Material |
|---|
| PVC - Polyvinyl Chloride | 0.281 in | 0.005 in | 0.035 in | Cotton Serve |
Construction and Dimensions
Cabling
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR |
|---|
| 10.2 Ohm/1000ft | 10.2 Ohm/1000ft | 3.47 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 23 pF/ft | 40 pF/ft |
Current
| Max. Recommended Current [A] |
|---|
| 3.2 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V RMS (UL AWM Style 2094) |
Temperature Range
| UL Temp Rating | 60°C |
|---|
| Operating Temperature Range | -20°C To +60°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 59 lbs/1000ft |
|---|
| Max. Pull Tension | 139 lbs |
|---|
| Min. Bend Radius/Minor Axis | 2.8 in |
|---|
Standards
| UL AWM Style Compliance | AWM 2094 (300 V 60°C) |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor (Not Riser or Plenum) |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1685 UL Loading, VW-1 |
|---|
| UL voltage rating | 300 V RMS (UL AWM Style 2094) |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
|---|
History
| Update and Revision | Revision Number: 0.384 Revision Date: 12-20-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Data Sheets