RG-303/U, 19 AWG solid .037" silver-coated copper-covered steel conductor, plenum, TFE insulation, silver-coated copper braid shield (95% coverage), FEP jacket, commercial non-QPL product.
Specifications
Specifications
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|
| 19 | Solid | SCCS - Silvered Copper Covered Steel | 0.037 in | 1 |
Insulation
| Material | Material Trade Name | Nominal Diameter |
|---|
| PTFE - Polytetrafluoroethylene | Teflon® | 0.116 in |
Outer Shield
| Type | Layer | Material | Coverage [%] |
|---|
| Braid | 1 | Silvered Copper (SC) | 95% |
Outer Jacket
| Material | Nominal Diameter |
|---|
| FEP - Fluorinated Ethylene Propylene | 0.17 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Conductor DCR Conductor Resistance | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|
| 16.3 Ohm/1000ft | 16.3 Ohm/1000ft | 4.3 Ohm/1000ft | 4.3 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 29 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.067 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 50 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|
| 1 MHz | 0.3 dB/100ft |
| 10 MHz | 1.1 dB/100ft |
| 50 MHz | 2.7 dB/100ft |
| 100 MHz | 3.9 dB/100ft |
| 200 MHz | 5.6 dB/100ft |
| 400 MHz | 8.2 dB/100ft |
| 700 MHz | 11 dB/100ft |
| 900 MHz | 12.5 dB/100ft |
| 1000 MHz | 13.5 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|
| 1.46 ns/ft | 70% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) |
|---|
| 50 MHz | 2.7 dB/100ft |
| 400 MHz | 8.6 dB/100ft |
| 1000 MHz | 15 dB/100ft |
| 3000 MHz | 28 dB/100ft |
Voltage
| Description | UL Voltage Rating | Voltage Rating [V] |
|---|
| MIL | 150 V RMS | 1400 V RMS (Mil Spec) |
VSWR
| Frequency [MHz] | Max. VSWR |
|---|
| 50 MHz - 1000 MHz | per M17/111-RG303 |
Temperature Range
| UL Temp Rating | 200°C |
|---|
| Operating Temperature Range | -70°C To +200°C |
|---|
Mechanical Characteristics
| Bulk Cable Weight | 30 lbs/1000ft |
|---|
| Max. Pull Tension | 112 lbs |
|---|
| Min. Bend Radius/Minor Axis | 2 in |
|---|
Standards
| NEC/(UL) Compliance | CL2P |
|---|
| RG Type | 303 |
|---|
| Military Compliance | Commercial, non-QPL product (M17/111-RG303) |
|---|
| Qualified Products List (QPL) | No |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Outdoor - Aerial |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/11/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | No |
|---|
| MII Order #39 (China RoHS) | Yes |
|---|
Suitability
| Suitability - Aerial | Yes - When supported by messenger wire |
|---|
| Suitability - Burial | No |
|---|
| Suitability - Hazardous Locations | No |
|---|
| Suitability - Indoor | Yes |
|---|
| Suitability - Outdoor | Yes |
|---|
| Suitability - Sunlight Resistance | No |
|---|
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
|---|
| UL voltage rating | 150 V RMS |
|---|
Plenum/Non-Plenum
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP., E - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'. |
|---|
History
| Update and Revision | Revision Number: 0.360 Revision Date: 11-09-2022 |
|---|
Documentation
Product Bulletins
Solution Guides
Tools
White Papers
Training
Data Sheets