Electronic, 1 Pair AWG 16 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Unshielded shielding, LSZH / FRNC jacket , 300V, SWA
Specifications
Specifications
Product Overview
Suitable Applications | Instrumentation and computer cable; For data transmission applications |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
16 | 19x29 | TC - Tinned Copper | 1 |
Conductor Count | 2 |
---|
Total Number of Pairs | 1 |
---|
Insulation
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
PE - Polyethylene | 2.67 mm | 0.05 mm |
Color Chart
Number | Color |
---|
Pair 1 | Black & White |
Inner Jacket
Material | Color | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | Chrome (RAL 7037) | 7.1 mm | 0.89 mm |
Outer Shield
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 11.5 mm | 1.3 mm |
Construction and Dimensions
Cabling
Description | Filler |
---|
1 pair and 2 fillers twisted to cable core covered with a polyester foil | Polypropylene (2x) (White, 2.29 mm) |
Armor
Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
---|
Steel Wire Armoring | Galvanized steel wire | 0.9 mm | Min. 95% |
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR |
---|
14.7 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor |
---|
108.3 pF/m |
Inductance
Nominal Pair Inductance |
---|
0.62 µH/m |
Current
Element | Max. Recommended Current [A] |
---|
Conductor(s) | 7.1 Amps per Conductor |
Voltage
Temperature Range
Storage Temperature Range | -30°C to +80°C |
---|
Operating Temp Range (Fixed Install) | -15°C To +80°C |
---|
Mechanical Characteristics
Oil Resistance | IEC 60811-404 |
---|
Min. Bend Radius During Installation | 172.5 mm |
---|
Standards
CPR Euroclass | Eca |
---|
CENELEC Compliance | EN 50290-2-20 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor |
---|
Suitability
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-3-24 |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|