Electronic, 1 Pair AWG 16 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Unshielded shielding, LSZH / FRNC jacket , 300V, SWA
Specifications
Specifications
Product Overview
| Suitable Applications | Instrumentation and computer cable; For data transmission applications |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 16 | 19x29 | TC - Tinned Copper | 1 |
| Conductor Count | 2 |
|---|
| Total Number of Pairs | 1 |
|---|
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| PE - Polyethylene | 2.67 mm | 0.05 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | Black & White |
Inner Jacket
| Material | Color | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | Chrome (RAL 7037) | 7.1 mm | 0.89 mm |
Outer Shield
Outer Jacket
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 11.5 mm | 1.3 mm |
Construction and Dimensions
Cabling
| Description | Filler |
|---|
| 1 pair and 2 fillers twisted to cable core covered with a polyester foil | Polypropylene (2x) (White, 2.29 mm) |
Armor
| Type of Armor | Material | Thickness of Armoring Wires | Coverage Percentage |
|---|
| Steel Wire Armoring | Galvanized steel wire | 0.9 mm | Min. 95% |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 14.7 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor |
|---|
| 108.3 pF/m |
Inductance
| Nominal Pair Inductance |
|---|
| 0.62 µH/m |
Current
| Element | Max. Recommended Current [A] |
|---|
| Conductor(s) | 7.1 Amps per Conductor |
Voltage
Temperature Range
| Storage Temperature Range | -30°C to +80°C |
|---|
| Operating Temp Range (Fixed Install) | -15°C To +80°C |
|---|
Mechanical Characteristics
| Oil Resistance | IEC 60811-404 |
|---|
| Min. Bend Radius During Installation | 172.5 mm |
|---|
Standards
| CPR Euroclass | Eca |
|---|
| CENELEC Compliance | EN 50290-2-20 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor |
|---|
Suitability
| Suitability - Sunlight Resistance | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-3-24 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
History
| Update and Revision | Revision Number: 0.221 Revision Date: 12-19-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets