Portable Cordage, 2 Conductor 18AWG (42x34) Bare Copper, EPDM Insulation, Rubber Outer Jacket, UL Type SJ
Specifications
Specifications
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Conductor(s) | 2 | 18 AWG | 42x34 | BC - Bare Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Conductor(s) | EPDM - Ethylene Propylene Diene Monomer | 0.0315 in (0.800 mm) | 0.110 in (2.79 mm) | Black, White |
Outer Shield
Outer Jacket
| Separator | Material | Nom. Thickness | Nom. Diameter |
|---|
| Paper Tape | SBR - Styrene Butadiene Rubber | 0.039 in (0.99 mm) | 0.298 in |
| Overall Cable Diameter (Nominal) | 0.298 in |
|---|
Electrical Characteristics
Electricals
| Nom. Conductor DCR | Max. Current |
|---|
| 6.97 Ohm/1000ft | 10 Amps per Conductor at 25ºC (7 Amps over 50 ft) |
Voltage
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 60°C | -20°C To +60°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 2.98 in (75.7 mm) | 2.98 in |
| Max. Pull Tension | 41 lbs (19 kg) |
|---|
| Bulk Cable Weight | 43 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor |
|---|
| NEC / UL Compliance | Article 400, SJ |
|---|
| AWM Compliance | SJ |
|---|
| CEC / C(UL) Compliance | LL7874 |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
History
| Update and Revision | Revision Number: 0.358 Revision Date: 05-05-2023 |
|---|
Documentation
Catalogs
Tools
Compliance Documentation
Data Sheets