Description
Electronic, 2 Conductor 12AWG (19x25) Tinned Copper, PE Insulation, Overall Beldfoil® Shield, PVC Outer Jacket, CL2
Specifications
Specifications
Product Overview
Suitable Applications | up to 600V analog signals ; up to 600V digital control ; line level audio; voice communications; panel wiring |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 1 | 12 AWG | 19x25 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Pair(s) | PE - Polyethylene | 0.037 in (0.94 mm) | 0.164 in (4.17 mm) | Black & Clear |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 14 AWG (19x26) TC |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC - Polyvinyl Chloride | 0.034 in (0.86 mm) | 0.400 in (10.2 mm) |
Overall Cable Diameter (Nominal) | 0.400 in (10.2 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Max. Current |
---|---|---|---|---|---|
Conductor(s) | 1.78 Ohm/1000ft | 25 pF/ft (82 pF/m) | 49 pF/ft (160 pF/m) | 55 Ohm | 30 Amps per Conductor at 30ºC |
Voltage
UL Voltage Rating |
---|
600 V (UL AWM 20253), 300 V (CSA AWM) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
80°C | -20°C to +80°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
4.0 in (100 mm) | 4.0 in (100 mm) |
Max. Pull Tension | 200 lbs (91 kg) |
---|---|
Bulk Cable Weight | 87 lbs/1000ft |
Standards and Compliance
Environmental Suitability | Indoor |
---|---|
Sustainability | CA Prop 65 |
Flammability / Reaction to Fire | UL 1685 UL loading , IEC 60332-1-2 |
CPR Compliance | CPR Euroclass: Eca |
NEC / UL Compliance | Article 725, CL2 |
AWM Compliance | AWM 20253 |
European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance | UKCA Mark |
APAC Compliance | China RoHS II (GB/T 26572-2011) |
History
Update and Revision | Revision Number: 0.529 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC |
Variant_Options 8718 060500: |
8718 060500|Chrome|Reel|500 ft|612825214212 |
Variant_Options 8718 060U500: |
8718 060U500|Chrome|UnReel|500 ft|612825214182 |
Variant_Options 8718 0601000: |
8718 0601000|Chrome|Reel|1,000 ft|612825214199 |
Variant_Options 8718 0602000: |
8718 0602000|Chrome|Reel|2,000 ft|612825214205 |
Variant_Options 8718 0605000: |
8718 0605000|Chrome|Reel|5,000 ft|612825214229 |