Electronic, 2 Conductor 16AWG (19x29) Tinned Copper, PE Insulation, Overall Beldfoil® Shield, LSZH Outer Jacket, CPR Cca
Specifications
Specifications
Product Overview
| Suitable Applications | up to 600V analog signals ; up to 600V digital control ; line level audio; voice communications; panel wiring |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 16 | 19x29 | TC - Tinned Copper | 1 |
Insulation
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | 3.1 mm | 0.07 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | Black & white |
Inner Shield
| Material | Drainwire Material | Drainwire AWG |
|---|
| Bi-Laminate (Alum+Poly) | TC - Tinned Copper | AWG18/16 |
Inner Jacket
| Material |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) |
Outer Shield
| Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | 9 / 23 µm | TC - Tinned Copper | 18 | Stranded |
Outer Jacket
| Material | Color | Nominal Diameter |
|---|
| LSZH - Low Smoke Zero Halogen (Flame Retardant) | Chrome (RAL 7037) | 8.30 mm |
| | 8.30 mm |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR |
|---|
| 14.76 Ohm/km |
Capacitance
| Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
|---|
| 110 pF/m | 200 pF/m |
Inductance
| Nominal Pair Inductance |
|---|
| 0.66 µH/m |
Current
| Element | Max. Recommended Current [A] |
|---|
| Conductor(s) | 7 Amps per Conductor at 25ºC |
Voltage
Temperature Range
| Operating Temperature Range | -20°C To +80°C |
|---|
| Operating Temp Range (Flexible Install) | -15°C To +80°C |
|---|
| Operating Temp Range (Fixed Install) | -45°C To +80°C |
|---|
Mechanical Characteristics
| Min. Bend Radius/Minor Axis | 85 mm |
|---|
Standards
| CPR Euroclass | Cca-s1a,d1,a1 |
|---|
| CENELEC Compliance | EN 50290-2-20 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor - Euroclass Cca |
|---|
| EU Directive 2000/53/EC (ELV) | Yes |
|---|
| EU Directive 2003/96/EC (BFR) | Yes |
|---|
| EU Directive 2011/65/EU (RoHS 2) | Yes |
|---|
| EU Directive 2012/19/EU (WEEE) | Yes |
|---|
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
|---|
| EU CE Mark | Yes |
|---|
Suitability
| Suitability - Indoor | Yes |
|---|
| Suitability - Non-Halogenated | Yes |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 |
|---|
| IEC 60754-1 - Halogen Amount | Zero |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 80% |
|---|
History
| Update and Revision | Revision Number: 0.45 Revision Date: 03-06-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Data Sheets