Audio, Control & Instrument Cable, 22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pairs, individually Beldfoil® shielded (100% coverage), 24 AWG stranded tinned copper drain wire, LSZH jacket, CPR Cca
Specifications
Specifications
Product Overview
Suitable Applications | low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
22 | 7x30 | TC - Tinned Copper | 2 |
Conductor Count | 4 |
---|
Total Number of Pairs | 2 |
---|
Insulation
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
PP - Polypropylene | 1.17 mm | 0.05 mm |
Color Chart
Number | Color |
---|
Pair 1 | Black & Red |
Pair 2 | Green & White |
Inner Shield
Type | Material | Material Trade Name | Coverage [%] | Thickness of Foil | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
---|
Tape | Bi-Laminate (Alum+Poly) | Beldfoil® (Z-Fold®) | 100% | 9 µm | TC - Tinned Copper | AWG24/7 | 7x32 |
Outer Jacket
Material | Nominal Diameter | Nominal Wall Thickness |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 5.60 mm | 1.1 mm |
Construction and Dimensions
Stranding
Cabling
Description |
---|
2 pairs twisted to cable core |
Electrical Characteristics
Conductor DCR
Individual Pair Nominal Shield DCR | Nominal Conductor DCR | Nominal Inner Shield DCR |
---|
15 Ohm/1000ft | 49.2 Ohm/km | 54.5 Ohm/km |
Capacitance
Nom. Capacitance Conductor to Conductor | Nom. Capacitance Conductor to Other Conductor to Shield |
---|
114.8 pF/m | 203.4 pF/m |
Inductance
Nominal Pair Inductance |
---|
0.56 µH/m |
Impedance
Nominal Characteristic Impedance |
---|
45 Ohm |
Delay
Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
---|
66 ns/100m | 66% |
Current
Element | Max. Recommended Current [A] |
---|
Conductor(s) | 2.3 Amps per Conductor |
Voltage
Temperature Range
Installation Temperature Range | -15°C To +80°C |
---|
Storage Temperature Range | -45°C To +80°C |
---|
Operating Temp Range (Flexible Install) | -15°C To +80°C |
---|
Operating Temp Range (Fixed Install) | -45°C To +80°C |
---|
Mechanical Characteristics
Oil Resistance | IEC 60811-404 |
---|
Max. Pull Tension | 226 N |
---|
Min. Bend Radius During Installation | 56 mm |
---|
Min. Bend Radius/Minor Axis | 2 in |
---|
Standards
CPR Euroclass | Cca-s1a,d1,a1 |
---|
CENELEC Compliance | EN 50290-2-20 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor - Euroclass Cca |
---|
EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
---|
EU CE Mark | Yes |
---|
MII Order #39 (China RoHS) | Yes |
---|
Suitability
Suitability - Indoor | Yes |
---|
Suitability - Non-Halogenated | Yes |
---|
Suitability - Sunlight Resistance | Yes |
---|
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2 |
---|
IEC 60754-1 - Halogen Amount | Zero |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 2.5 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 80% |
---|
History
Update and Revision | Revision Number: 0.54 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Catalogs
Brochures