Belden
8761 - Electronic, 2 C #22 Str TC, PE Ins, OS, PVC Jkt, CM
- SKU:
- 8761
- Shipping:
- Calculated at Checkout
Description
Electronic, 2 Conductor 22AWG (7x30) Tinned Copper, PE Insulation, Overall Beldfoil® Shield, PVC Outer Jacket, CM
Specifications
Specifications
Product Overview
Suitable Applications | low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 1 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Pair(s) | PE - Polyethylene | 0.017 in (0.43 mm) | 0.062 in (1.6 mm) | Black, Clear |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC - Polyvinyl Chloride | 0.025 in (0.64 mm) | 0.175 in (4.45 mm) |
Overall Cable Diameter (Nominal) | 0.175 in (4.45 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Max. Current |
---|---|---|---|---|---|
Pair(s) | 18.2 Ohm/1000ft | 24 pF/ft (79 pF/m) | 47 pF/ft (150 pF/m) | 64 Ohm | 6 Amps per Conductor at 30ºC |
Voltage
UL Voltage Rating |
---|
300 V (CM), 300 V (UL AWM 2092)) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
60°C | -20°C to +60°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
1.8 in (46 mm) | 1.8 in (46 mm) |
Max. Pull Tension | 27.3 lbs (12.4 kg) |
---|---|
Bulk Cable Weight | 16 lbs/1000ft |
Standards and Compliance
Environmental Suitability | Indoor |
---|---|
Flammability / Reaction to Fire | UL 1685 UL loading , IEC 60332-1-2 |
CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
NEC / UL Compliance | Article 800, CM |
AWM Compliance | AWM 2092 |
CEC / C(UL) Compliance | CM |
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance | UKCA Mark |
Plenum Number | 88761, 87761, 82761 |
History
Update and Revision | Revision Number: 0.532 Revision Date: 03-04-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC/EAN |
Variant_Options 8761.00U152: |
8761.00U152|Chrome|UnReel|152 m|8719605018946 |
Variant_Options 8761.01152: |
8761.01152|Chrome|Reel|152 m|8719605018960 |
Variant_Options 8761.00U305: |
8761.00U305|Chrome|UnReel|305 m|8719605018953 |
Variant_Options 8761.01305: |
8761.01305|Chrome|Reel|305 m|8719605018977 |
Variant_Options 8761 060500: |
8761 060500|Chrome|Reel|500 ft|612825215301 |
Variant_Options 8761 060U500: |
8761 060U500|Chrome|UnReel|500 ft|612825215240 |
Variant_Options 8761.01610: |
8761.01610|Chrome|Reel|610 m|8719605018984 |
Variant_Options 8761 0601000: |
8761 0601000|Chrome|Reel|1,000 ft|612825215257 |
Variant_Options 8761 060U1000: |
8761 060U1000|Chrome|UnReel|1,000 ft|612825215233 |
Variant_Options 8761 0602000: |
8761 0602000|Chrome|Reel|2,000 ft|612825215295 |
Variant_Options 8761 0605000: |
8761 0605000|Chrome|Reel|5,000 ft|612825215318 |
Variant_Options 8761 06010000: |
8761 06010000|Chrome|Reel|10,000 ft|612825215264 |
Variant_Options 8761 06015000: |
8761 06015000|Chrome|Reel|15,000 ft|612825215288 |