Belden

8770ELW - Electronic, 3C #18 Str TC, PO ins, OS, LSNH Jkt 300V, Cca

(No reviews yet) Write a Review
SKU:
8770ELW
Shipping:
Calculated at Checkout
$0.00

Description

Electronic, 3 Conductor AWG 18 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil(s) or Copper Tape(s) shielding, LSZH / FRNC jacket , 300V, Cca

Specifications

Specifications

Product Overview

Suitable ApplicationsAudio, Control & Instrumentation cable; For data transmission applications

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Conductors
1816x30TC - Tinned Copper3
Conductor Count3

Insulation

MaterialNominal DiameterDiameter +/- ToleranceNominal Wall Thickness
PE - Polyethylene2.08 mm0.05 mm0.018 in

Color Chart

NumberColor
Wire 1Black
Wire 2Red
Wire 3Clear

Outer Shield

TypeMaterialMaterial Trade NameCoverage [%]Thickness of FoilDrainwire MaterialDrainwire AWGDrainwire Construction n x D
TapeBi-Laminate (Alum+Poly)Beldfoil® (Z-Fold®)100%9 / 12 µmTC - Tinned CopperAWG20/7Stranded

Outer Jacket

MaterialNominal DiameterNominal Wall Thickness
LSZH - Low Smoke Zero Halogen (Flame Retardant)6.25 mm0.84 mm

Construction and Dimensions

Cabling

DescriptionTwists
3 wires twisted to cable core8 twist/ft

Electrical Characteristics

Conductor DCR

Nominal Conductor DCRNominal Outer Shield DCR
21.7 Ohm/km27.9 Ohm/km

Capacitance

Nom. Capacitance Conductor to ConductorNom. Capacitance Conductor to Other Conductor to Shield
78.7 pF/m157.5 pF/m

Inductance

Nominal Inductance
0.605 µH/m

Impedance

Nominal Characteristic Impedance
69 Ohm

Delay

Nominal Velocity of Propagation (VP) [%]
66%

Current

ElementMax. Recommended Current [A]
Conductor(s)5.3 Amps per Conductor

Voltage

Voltage Rating [V]
300 V

Temperature Range

Installation Temperature Range-15°C To +80°C
Storage Temperature Range-45°C To +80°C
Operating Temp Range (Flexible Install)-15°C To +80°C
Operating Temp Range (Fixed Install)-45°C To +80°C

Mechanical Characteristics

Oil ResistanceIEC 60811-404
Max. Pull Tension335 N
Min. Bend Radius During Installation62.5 mm
Min. Bend Radius/Minor Axis2.5 in

Standards

CPR EuroclassCca-s1,d1,a1
CENELEC ComplianceEN 50290-2-20

Applicable Environmental and Other Programs

Environmental SpaceIndoor - Euroclass Cca
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
MII Order #39 (China RoHS)Yes

Suitability

Suitability - IndoorYes
Suitability - Non-HalogenatedYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

IEC FlammabilityIEC 60332-1-2
IEC 60754-1 - Halogen AmountZero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity2.5 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%

Plenum/Non-Plenum

Plenum (Y/N)No

History

Update and RevisionRevision Number: 0.29 Revision Date: 03-14-2023