Audio, Control & Instrument Cable, 3-Pair, 22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, individually shielded pairs (100% coverage), 22 AWG stranded tinned copper drain wire, LSZH jacket, Steel Wire Armor
Specifications
Specifications
Product Overview
Suitable Applications | low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
---|
Construction Details
Conductor
Size | Stranding | Material |
---|
22 | 7x30 | TC - Tinned Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|
PP - Polypropylene | 1.27 mm (0.0500 in) | Black & Red, Black & White, Black & Green |
| | Red, Green, Blue |
Inner Shield
Shield Type | Material | Coverage | Drainwire Type | Notes |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC | each pair |
| Polyester | | | each pair |
Outer Shield
Material |
---|
Bi-Laminate (Alum+Poly) |
Inner Jacket
Material | Nom. Thickness | Nom. Diameter | Color |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 0.89 mm (0.035 in) | 7 mm (0.28 in) | Chrome (RAL 7037) |
Armor
Armor Type & Material | Armor Thickness | Coverage |
---|
SWA - Steel Wire Armor | 0.9 mm (0.035 in) | Min. 95% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
LSZH - Low Smoke Zero Halogen (Flame Retardant) | 1.35 mm (0.0531 in) | 11.5 mm (0.453 in) |
Overall Cable Diameter (Nominal) | 11.5 mm (0.453 in) |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Max. Current |
---|
49.2 Ohm/km (15.0 Ohm/1000ft) | 34.8 Ohm/km (10.6 Ohm/1000ft) | 98.4 pF/m (30.0 pF/ft) | 180.4 pF/m (54.99 pF/ft) | 50 Ohm | 2 A |
Mechanical Characteristics
Temperature
Operating | Installation | Storage |
---|
-45°C To +80°C | -15°C To +80°C | -45°C To +80°C |
Bend Radius
Installation Min. |
---|
115 mm (4.53 in) |
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance |
---|
Flammability / Reaction to Fire | IEC 60332-1-2, IEC 60332-3-24 |
---|
ISO/IEC Compliance | IEC 61034-2 - Smoke Density Min Transmittance = 60% |
---|
CENELEC Compliance | EN 50290-2-20 |
---|
European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 |
---|
European Directive Compliance | EU CE Mark |
---|
History
Update and Revision | Revision Number: 0.232 Revision Date: 03-04-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets