8 Conductor 24 AWG stranded (7x32) TC, shielded quads, polyethylene insulation, 24 AWG stranded TC drain wire; 2 Conductor 22 AWG stranded (7x30) TC , Unshielded, PVC insulation, PVC jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|
| Conductor(s) | 8 | 24 AWG | 7x32 | TC - Tinned Copper |
| Conductor(s) | 2 | 22 AWG | 7x30 | TC - Tinned Copper |
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|
| Conductor(s) | PE - Polyethylene | 0.012 in (0.30 mm) | 0.048 in (1.2 mm) | Red Quad, White, Green Quad, Blue |
| Conductor(s) | PVC - Polyvinyl Chloride | 0.015 in (0.38 mm) | 0.060 in (1.5 mm) | Gray, White, Blue, Green, Red Beldfoil®, Brown, Red, Yellow, Orange, Green Beldfoil®, White, Blue, Unshielded |
Inner Shield
| Element | Shield Type | Material | Coverage | Drainwire Type |
|---|
| Over Quad | Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
| Over Quad | Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC |
| Table Notes | Gray, White, Blue, Green; Brown, Red, Yellow, Orange; White, Blue |
|---|
Outer Shield
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|
| PVC - Polyvinyl Chloride | 0.03 in (0.76 mm) | 0.29 in |
| Overall Cable Diameter (Nominal) | 0.29 in. |
|---|
Electrical Characteristics
Electricals
| Nom. Conductor DCR | Nom. Inner Shield DCR | Max. Current |
|---|
| 28.7 Ohm/1000ft | 15.79 Ohm/1000ft (51.80 Ohm/km) | 1.5 Amps per Conductor at 25°C (24 AWG) |
| 15 Ohm/1000ft (49 Ohm/km) | 15.79 Ohm/1000ft (51.80 Ohm/km) | 3 Amps per Conductor at 25ºC (22 AWG) |
Voltage
Mechanical Characteristics
Temperature
Bend Radius
| Stationary Min. | Installation Min. |
|---|
| 2.9 in (74 mm) | 2.9 in |
| Max. Pull Tension | 51.2 lbs (23.2 kg) |
|---|
| Bulk Cable Weight | 45 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor (Not Riser or Plenum), Indoor |
|---|
| Flammability / Reaction to Fire | VW-1, IEC 60332-1-2 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
Product Notes
| Notes | Inner Beldfoil« shield over 24 AWG quads. Each quad wrapped in transparent polyester tape. Red Beldfoil« shield over one quad, Green Beldfoil« shield over the other. (2) quads and (2) unshielded conductors cabled. |
|---|
History
| Update and Revision | Revision Number: 0.359 Revision Date: 12-20-2022 |
|---|
Documentation
Product Bulletins
Catalogs
Technical Resources
Compliance Documentation
Data Sheets