Audio, Control & Instrument Cable, 22 AWG stranded (7x30) tinned copper conductors, FEP insulation, twisted pairs, individually Beldfoil® shielded (100% coverage), 24 AWG stranded (7x32) tinned copper drain wire, FEP jacket.
Specifications
Specifications
Product Overview
| Suitable Applications | extreme high/low temperature environments; chemical resistant; outdoor and burial applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; voice communications; panel wiring | 
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | 
|---|
| Pair(s) | 2 | 22 AWG | 7x30 | TC - Tinned Copper | 
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | 
|---|
| Pair(s) | FEP - Fluorinated Ethylene Propylene | 0.007 in (0.18 mm) | 0.042 in (1.1 mm) | Black & Red, Green & White | 
Inner Shield
| Element | Shield Type | Material | Coverage | Drainwire Type | Notes | 
|---|
| Pair(s) | Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC | each pair | 
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | 
|---|
| FEP - Fluorinated Ethylene Propylene | 0.015 in (0.38 mm) | 0.15 in (3.8 mm) | 
| Overall Cable Diameter (Nominal) | 0.15 in (3.8 mm) | 
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current | 
|---|
| Pair(s) | 18.2 Ohm/1000ft | 17.42 Ohm/1000ft (57.15 Ohm/km) | 35 pF/ft (110 pF/m) | 67 pF/ft (220 pF/m) | 40 Ohm | 69% | 2.8 Amps per Conductor at 25ºC | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V (CMP) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 150°C | -70°C to +200°C | 
Bend Radius
| Stationary Min. | Installation Min. | 
|---|
| 1.5 in (38 mm) | 1.5 in (38 mm) | 
| Max. Pull Tension | 42 lbs (19 kg) | 
|---|
| Bulk Cable Weight | 19 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Sunlight Resistance, UV Resistance, Oil Resistance | 
|---|
| Flammability / Reaction to Fire | NFPA 262 (UL910), FT6, IEC 60332-1-2 | 
|---|
| CPR Compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca | 
|---|
| NEC / UL Compliance | Article 800, CMP | 
|---|
| CEC / C(UL) Compliance | CMP | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| UK Regulation Compliance | UKCA Mark | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
| Non-Plenum Number | 8723 | 
|---|
Product Notes
| Notes | Non.conduit. Gas/vapor-tight jacket. | 
|---|
History
| Update and Revision | Revision Number: 0.548    Revision Date: 04-19-2023 | 
|---|