Twinax 100Ω, 1 Pair, 20 AWG (7x28) one tinned, one bare copper conductor, FEP insulation, FEP inner jacket, Duofoil® + tinned copper braid shield 85%, FEP jacket, CMP
Specifications
Specifications
Product Overview
| Suitable Applications | Computer, Instrumentation |
|---|
Construction Details
Conductor
| Size | Stranding | Nom. Diameter | Material |
|---|
| 20 AWG | 7x28 | 0.036 in | TC - Tinned Copper |
| 20 AWG | 7x28 | 0.036 in | BC - Bare Copper |
Insulation
| Material | Nom. Insulation Diameter | Color Code | Notes |
|---|
| FEP - Fluorinated Ethylene Propylene | 0.072 in (1.8 mm) | Clear | FEP on both conductors |
| FEP - Fluorinated Ethylene Propylene | 0.201 in (5.11 mm) | Clear | FEP over pair |
Outer Shield
| Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
|---|
| 1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
| 2 | Braid | Tinned Copper (TC) | | 85% |
Outer Jacket
| Material | Nom. Diameter |
|---|
| FEP - Fluorinated Ethylene Propylene | 0.259 in (6.58 mm) |
| Overall Cable Diameter (Nominal) | 0.259 in (6.58 mm) |
|---|
Electrical Characteristics
Attenuation
| Frequency | Nom. Attenuation |
|---|
| 1 MHz | 0.30 dB/100m |
| 10 MHz | 1.20 dB/100m |
| 50 MHz | 2.80 dB/100m |
| 100 MHz | 4.10 dB/100m |
| 200 MHz | 6.40 dB/100m |
| 300 MHz | 8.40 dB/100m |
| 400 MHz | 10.20 dB/100m |
Electricals
| Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Cond (Mutual) | Nom. Capacitance
Cond-to-Shield | Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|
| 9.5 Ohm/1000ft | 2.5 Ohm/1000ft (8.2 Ohm/km) | 14.0 pF/ft (45.9 pF/m) | 23.0 pF/ft (75.5 pF/m) | 100 Ohm | 70% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|
| 200°C | -70°C to +200°C |
Bend Radius
| Installation Min. |
|---|
| 3.0 in (76 mm) |
| Max. Pull Tension | 88 lbs (40 kg) |
|---|
| Bulk Cable Weight | 52 lbs/1000ft |
|---|
Standards and Compliance
| Environmental Suitability | Indoor - Plenum, Indoor |
|---|
| Sustainability | CA Prop 65 |
|---|
| Flammability / Reaction to Fire | NFPA 262 |
|---|
| CPR Compliance | CPR Euroclass: Eca |
|---|
| NEC / UL Compliance | CMP |
|---|
| CEC / C(UL) Compliance | CMP |
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
|---|
| UK Regulation Compliance | UKCA Mark |
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
|---|
| Non-Plenum Number | 9207 |
|---|
History
| Update and Revision | Revision Number: 0.486 Revision Date: 05-31-2023 |
|---|
Documentation
Product Bulletins
Catalogs
Compliance Documentation
Data Sheets