Blue Hose® for Data Highway Plus, 1 Pair 20AWG (7x28) Tinned Copper, FEP Insulation Blue & Clear, Overall Beldfoil®+Tinned Copper Braid(76%) Shield, FEP Inner Jacket, CCA Interlock Armor, Blue PVC Outer Jacket, CMP
Specifications
Specifications
Product Overview
Suitable Applications | extreme temp, exposure to oil and gasoline, harsh environment, Allen Bradley Data Highway communication interface between PLC processors, I/O devices, operator interfaces, computers and other intelligent devices, PLC processor interlocking, peer-to-peer messaging, remote programming, troubleshooting, I/O updates, etc. |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 1 | 20 AWG | 7x28 | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|
Pair(s) | FEP - Fluorinated Ethylene Propylene | 0.0175 in (0.445 mm) | 0.073 in (1.9 mm) | Clear & Blue | Twinax with rod fillers |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 20 AWG (7x28) TC |
Braid | Tinned Copper (TC) | 76% | |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|
FEP - Fluorinated Ethylene Propylene | 0.015 in (0.38 mm) | 0.203 in (5.16 mm) |
Overall Cable Diameter (Nominal) | 0.203 in (5.16 mm) |
---|
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
---|
Pair(s) | 9.5 Ohm/1000ft | 19.7 pF/ft (64.6 pF/m) | 37 pF/ft | 78 Ohm | 69% |
Nom. Outer Shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
---|
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|
Pair(s) | 1 | 0.6 dB/100ft |
| 10 | 2.1 dB/100ft |
| 50 | 5 dB/100ft |
| 100 | 7.5 dB/100ft |
| 200 | 11 dB/100ft |
| 400 | 16 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V (CMP, CL2P) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
200°C | -70°C to +200°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
2.5 in (64 mm) | 2.5 in (64 mm) |
Max. Pull Tension | 48 lbs (22 kg) |
---|
Bulk Cable Weight | 34 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor |
---|
Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 725, Article 800 |
---|
CEC / C(UL) Compliance | CMP |
---|
European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Other Standard Compliance(s) | Allen Bradley Part No. 1770-CD |
---|
Non-Plenum Number | 9463 |
---|
History
Update and Revision | Revision Number: 0.487 Revision Date: 01-20-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets