RS-485, 1 Pair 24AWG (7x32) Tinned Copper, FEP Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, FEP Outer Jacket, CMP
Specifications
Specifications
Product Overview
| Suitable Applications | RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. | 
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material | 
|---|
| Pair(s) | 1 | 24 AWG | 7x32 | TC - Tinned Copper | 
Insulation
| Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | 
|---|
| Pair(s) | FEP - Fluorinated Ethylene Propylene (Foam) | 0.025 in (0.64 mm) | 0.074 in (1.9 mm) | White/Blue Stripe & Blue/White Stripe | 
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type | 
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 24 AWG (7x32) TC | 
| Braid | Tinned Copper (TC) | 90% |  | 
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter | 
|---|
| FEP - Fluorinated Ethylene Propylene | 0.015 in (0.38 mm) | 0.204 in (5.18 mm) | 
| Overall Cable Diameter (Nominal) | 0.204 in (5.18 mm) | 
|---|
Electrical Characteristics
Electricals
| Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current | 
|---|
| Pair(s) | 24 Ohm/1000ft | 12 pF/ft (39 pF/m) | 22 pF/ft | 120 Ohm | 76% | 4 Amps per Conductor at 25ºC | 
| Nom. Outer Shield DCR | 3.1 Ohm/1000ft (10 Ohm/km) | 
|---|
High Frequency (Nominal/Typical)
| Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) | 
|---|
| Pair(s) | 1 | 0.6 dB/100ft | 
Voltage
| UL Voltage Rating | 
|---|
| 300 V (CMP) | 
Mechanical Characteristics
Temperature
| UL Temperature | Operating | 
|---|
| 200°C | -70°C to +200°C | 
Bend Radius
| Stationary Min. | Installation Min. | 
|---|
| 2.25 in (57.2 mm) | 2.25 in (57.2 mm) | 
| Max. Pull Tension | 45.7 lbs (20.7 kg) | 
|---|
| Bulk Cable Weight | 27 lbs/1000ft | 
|---|
Standards and Compliance
| Environmental Suitability | Indoor, Oil Resistance | 
|---|
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 | 
|---|
| CPR Compliance | CPR Euroclass: Eca | 
|---|
| NEC / UL Compliance | Article 800, CMP | 
|---|
| CEC / C(UL) Compliance | CMP | 
|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) | 
|---|
| UK Regulation Compliance | UKCA Mark | 
|---|
| APAC Compliance | China RoHS II (GB/T 26572-2011) | 
|---|
| Non-Plenum Number | 9841, 9841ZH | 
|---|
Product Notes
| Notes | Oil and Gas Resistant | 
|---|
History
| Update and Revision | Revision Number: 0.570    Revision Date: 04-28-2023 | 
|---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets