Computer POS Cable, 22 AWG solid tinned copper conductors, solid FEP insulation, twisted pairs, overall Beldfoil® (100% coverage) + tinned copper braid shield (55% coverage) + polyester tape, 22 AWG solid tinned copper drain wire, FEP jacket, plenum rated
Specifications
Specifications
Product Overview
Suitable Applications | point of sale; rs-485 applications; extreme high/low temperature environments; computer communication; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; panel wiring |
---|
Construction Details
Conductor
Element | Number of Element | Size | Stranding | Material |
---|
Pair(s) | 2 | 22 AWG | Solid | TC - Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|
Pair(s) | FEP - Fluorinated Ethylene Propylene | 0.016 in (0.41 mm) | 0.058 in (1.5 mm) | Red & Blue, Black & Yellow |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (Solid) TC |
Braid | Tinned Copper (TC) | 56% | |
Table Notes | Polyester Tape |
---|
Outer Jacket
Material | Nom. Thickness | Nom. Diameter | Ripcord |
---|
FEP - Fluorinated Ethylene Propylene | 0.016 in (0.41 mm) | 0.272 in | Yes |
Overall Cable Diameter (Nominal) | 0.272 in |
---|
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|
20.6 Ohm/1000ft | 15.5 pF/ft (50.9 pF/m) | 27 pF/ft (89 pF/m) | 100 Ohm | 70% | 4.8 Amps per Conductor at 30ºC |
Voltage
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|
200°C | -70°C to +200°C |
Bend Radius
Stationary Min. | Installation Min. |
---|
2.72 in (69.1 mm) | 2.72 in |
Max. Pull Tension | 65 lbs (29 kg) |
---|
Bulk Cable Weight | 38 lbs/1000ft |
---|
Standards and Compliance
Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance |
---|
Flammability / Reaction to Fire | NFPA 262 (UL 910), FT6, IEC 60332-1-2 |
---|
CPR Compliance | CPR Euroclass: Eca |
---|
NEC / UL Compliance | Article 800, CMP |
---|
CEC / C(UL) Compliance | CMP |
---|
European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
---|
UK Regulation Compliance | UKCA Mark |
---|
APAC Compliance | China RoHS II (GB/T 26572-2011) |
---|
Non-Plenum Number | 9855 |
---|
History
Update and Revision | Revision Number: 0.349 Revision Date: 05-05-2023 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Compliance Documentation
Data Sheets