Belden

89907 - Thinnet 10BASE2, RG-58A/U Type, #20 Str, FFEP, Duobond II+TC Braid, PVDF Jkt, CMP

(No reviews yet) Write a Review
SKU:
89907
Shipping:
Calculated at Checkout
$0.00

Description

IEEE 802.3 Ethernet Thinnet 10BASE2, 20 AWG (19x32) tinned copper conductor, foam FEP insulation, Duobond® II (100% coverage) + tinned copper braid shield (95% coverage), fluorocopolymer jacket, CMP

Specifications

Specifications

Product Overview

Suitable ApplicationsThin Ethernet (IEEE 802.3 10BASE2)

Construction Details

RG Type58

Conductor

SizeStrandingNom. DiameterMaterial
20 AWG19x320.037 inTC - Tinned Copper

Insulation

MaterialNom. Insulation DiameterColor Code
PFA - Perfluoroalkoxy (Foam)0.100 in (2.54 mm)White

Outer Shield

LayerOuter Shield TypeMaterialMaterial Trade NameCoverage
1TapeTri-Laminate (Alum+Poly+Alum)Duobond® II100%
2BraidTinned Copper (TC)93%

Outer Jacket

MaterialNom. Diameter
PVDF - Polyvinylidene Fluoride0.165 in (4.19 mm)
Overall Cable Diameter (Nominal)0.165 in (4.19 mm)

Electrical Characteristics

Attenuation

FrequencyNom. Attenuation
1 MHz0.43 dB/100ft
10 MHz1.3 dB/100ft
50 MHz2.91 dB/100ft
100 MHz4.18 dB/100ft
200 MHz6.1 dB/100ft
400 MHz9.2 dB/100ft
700 MHz12.9 dB/100ft
900 MHz15.0 dB/100ft
1000 MHz16.0 dB/100ft

Power Rating

FrequencyMax. Power Rating
1 MHz6,450 W
10 MHz1,850 W
50 MHz890 W
100 MHz640 W
200 MHz470 W
400 MHz360 W
700 MHz290 W
900 MHz270 W
1,000 MHz260 W

Electricals

Nom. Conductor DCRNom. Outer Shield DCRNom. Capacitance Cond-to-ShieldNom. Characteristic ImpedanceNom. Velocity of Prop.
8.5 Ohm/1000ft (28 Ohm/km)5.8 Ohm/1000ft (19 Ohm/km)26.0 pF/ft (85.3 pF/m)50 Ohm80%

Voltage

UL Voltage Rating
300 V (CMP)

Mechanical Characteristics

Temperature

UL TemperatureOperating
150°C-15°C to +150°C

Bend Radius

Installation Min.
1.6 in (41 mm)
Max. Pull Tension45 lbs (20 kg)
Bulk Cable Weight26 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor - Plenum, Aerial - When supported by messenger wire
SustainabilityCA Prop 65
Flammability / Reaction to FireNFPA 262
CPR ComplianceCPR Euroclass: Eca
CEC / C(UL) ComplianceCMP
IEEE Compliance802.3 10Base2
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number9907

History

Update and RevisionRevision Number: 0.519 Revision Date: 05-31-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC
Variant_Options 89907 E4X500:
89907 E4X500|Gray, Light Dec|Reel|500 ft|612825221449
Variant_Options 89907 E4X1000:
89907 E4X1000|Gray, Light Dec|Reel|1,000 ft|612825221425
Variant_Options 89907 E4X2500:
89907 E4X2500|Gray, Light Dec|Reel|2,500 ft|612825221432
View AllClose